FORD EEC-V • 216K
Professional calibration definition • Version 1.0
A large Ford EEC-V 216K calibration definition containing nearly 1,600 manually mapped and checked parameters. Built as a reference for tuning, calibration development, definition creation, binary analysis and reverse engineering.
Buy Definition - $600THE DEFINITION
The Ford EEC-V 216K platform contains a substantial amount of calibration and control data spread throughout the PCM firmware. Finding, identifying and correctly interpreting that information from scratch can take an enormous amount of time.
This definition contains nearly 1,600 mapped calibration parameters organized into useful categories. The definition includes scalars, tables, switches, constants, parameters and other identified calibration data.
The mapping was built through manual research and reverse engineering of EEC-V 216K firmware. Parameters are located, analyzed and checked rather than simply being generated from an automated address scan.
Thousands of hours of research and development have gone into understanding Ford calibration structures, locating calibration data, identifying parameters, checking addresses and building this definition into a practical foundation for further work.
A large collection of identified EEC-V 216K calibration locations gives you a substantial head start when working with compatible Ford PCM binaries.
Parameters have been manually located, analyzed and checked. The goal is useful, accurate calibration information rather than simply generating thousands of automatically detected addresses.
The mapped information can be used as the foundation for creating your own XDF, DAMOS, A2L-style definition, WinOLS project or another calibration format supported by your workflow.
Use the mapped information while analyzing EEC-V firmware, following code references, identifying calibration structures and understanding how the PCM is organized.
Where identified, the definition includes useful information such as parameter names, data types, dimensions, conversions, scaling and other calibration details.
USE THE DATA YOUR WAY
The definition is provided as calibration data and reference information rather than being locked to one specific tuning application. Use the mapped information to build or work with the format that makes sense for your project.
COMPATIBILITY
Any Ford vehicle and calibration strategy using the EEC-V 216K PCM platform is supported. The definition is not limited to a fixed list of strategy IDs.
DEFINITION PREVIEW
Browse the categories and parameters included in the definition. This public preview shows the category, manufacturer parameter name and readable name while keeping the underlying calibration data private.
| Manufacturer Name | Name |
|---|---|
| ACPRES_SH | AC Head Pressure Level Inhibits Clutch |
| ACPRES_CL | AC Head Pressure Level Restores Clutch |
| Manufacturer Name | Name |
|---|---|
| DPS_FK_IN | Accelerator Pump Filter For Tip In |
| DPS_FK_OUT | Accelerator Pump Filter For Tip Out |
| DPS_GP | Accelerator Pump Multiplier For Tip In |
| DPS_GN | Accelerator Pump Multiplier For Tip Out |
| DPS_POS | Accelerator Pump Tip In Threshold |
| DPS_NEG | Accelerator Pump Tip Out Threshold |
| FN123D | Pump Shot Gain With Coolant Temp |
| Manufacturer Name | Name |
|---|---|
| FADPT_SW | Fuel Adaptation Switch |
| FN1325A | Adaptive Fuel Table |
| FN1325A | Adaptive Fuel Table AM |
| FN1325A | Adaptive Fuel Table Load |
| AFACT2 | Highest Adaptation ACT Allowed During Adaptation |
| AFECT2 | Highest Adaptation ECT Allowed During Adaptation |
| AFACT1 | Lowest Adaptation ACT Allowed During Adaptation |
| AFECT1 | Lowest Adaptation ECT Allowed During Adaptation |
| ADAPT_SEL | Adaptive Select Switch |
| FN1327A | Adaptive-injector Mapping |
| ADAPTM | ADAPTM |
| ADEFTR | Adaptive Fuel Error Trim |
| MAXADP | Adaptive Compensation Max Allowed Learned |
| MINADP | Adaptive Compensation Min Allowed Learned |
| DELAMB | Dead Band To Not Adapt |
| ADPTP | Max Tp Allowed During Adaptation |
| VECT3 | Min ECT During Adaptation |
| ADPLOD | Min Engine Load Allowed During Adaptation |
| KWUCNT | Number Of Warm Up Counters For Fast Adaptation |
| KAM_NO_RESET | Switch To Shut Off Kam Fuel Reset |
| VECT5 | Warm Up Temperature During Adaptation After Beginning |
| FN070D | Xnorm Adaptive Learning 01 |
| FN041 | Ynorm Fuel Adaptive Table Am |
| FN021A | Ynorm Fuel Adaptive Table Load |
| Manufacturer Name | Name |
|---|---|
| TCC_CKT_UP | Converter Solenoid Circuit Test Up Counter |
| TCC_EO_LVL | Converter Solenoid Open Test Limit |
| P1746UP | P1746 Fault Up Counter |
| SS_CKT_UP | Shift Solenoid Circuit Test Up Counter |
| SS_EO_LVL | Shift Solenoid Open Test Limit |
| TOT_ERRP_LVL | TOT Circuit Fault Limit |
| TOT_EOP_LVL | TOT Circuit Fault Limit Engine Off |
| TRNS_EO_LVL | Trans Engine On Level |
| TRS_EOW_LVL | Transmission Range Sensor Engine Off Deviation Level |
| TRS_ERRW_LVL | Transmission Range Sensor Deviation Level |
| TRS_TRNS_LVL | Transmission Range Sensor Trans Error Level |
| VFS1_BAT_UP | VFS 1 Short To Power Up Counter |
| Manufacturer Name | Name |
|---|---|
| RT_AXLE | Axle Ratio |
| AXLE_RATIO_I | Axle Ratio Integer Value |
| NOV_VID_SW | Axle Ratio Switch |
| TIRE_REV | Tire Revs Per Mile |
| AXLE_RATIO_F | Traction Control Switch |
| Manufacturer Name | Name |
|---|---|
| FN821 | Idle RPM Using Low Voltage Level Duration |
| IS_BATV_DR | Max Battery Idle Speed Clamp Drive |
| LOWVOL_CH | Voltage Threshold For Charging System Healthy State |
| LOWVOL_SL | Voltage Threshold For Low Charging State |
| Manufacturer Name | Name |
|---|---|
| ROM_TO | Checksum Equalizer |
| Manufacturer Name | Name |
|---|---|
| SPK_DTS_LIM | Clock Tics To Update Ignition Timing Less Often |
| SPK_DEG_DIF | Difference To Update Ignition Timing Less Often |
| N_PIP_SKIP | Number Of PIPs To Skip In Less Frequent Mode |
| FULPIPALT_DT | PIP To Change To Half Fueling Updates |
| FULPIPMEG_DT | PIP To Change To Less Frequent Fuel Updates |
| MEGAPIP_H_DT | PIP To Return To Half Fueling |
| ALTPIP_H_DT | PIP To Return To Normal Fueling |
| Manufacturer Name | Name |
|---|---|
| JUMP_FRAC | Quantity Of Fraction To Jump To |
| AMP_MULT | Amplitude Multiplier |
| HOLD_TM_PCTA | Fraction Of Learned Delay Used |
| LAM_MOD_MAX | Max Cal Of Fuel Modulation |
| DYN_LMAX_LL | Max Cal Of Short Term Trim |
| MAX_ROA_L | Max Cal Of Short Term Fuel Trim Lean Direction |
| MAX_ROA_R | Max Cal Of Short Term Fuel Trim Rich Direction |
| LAM_MOD_MIN | Min Cal Of Fuel Modulation |
| DYN_LMIN_UL | Min Cal Of Short Term Trim |
| JUMP_MULT | Multiplier Of Fraction To Jump To |
| FN1352 | Peak To Peak Amplitude For Feedback |
| PTPAMP_FK | Peak To Peak Filter Constant |
| PTPERROR_MAX | Peak To Peak Max Error Allowed |
| PTPERROR_MIN | Peak To Peak Min Error Allowed |
| RR_MULT_GAIN | Proportional Gain Cal Multiplier |
| FN039 | Xnorm Feedback Fuel Control 01 |
| FN021 | Ynorm Feedback Fuel Control 01 |
| Manufacturer Name | Name |
|---|---|
| FN052C | Cylinder Air Charge During Crank |
| FNCRKMUL_FAR | Crank Fuel Multiplier With Time FAR |
| FN884 | Crank ISC Duty Cycle |
| FNCRK_LAMS | Crank Lambda |
| FN2500 | Cranking Ignition Timing |
| CRK_PIP_ECT | CRK Profile Ignition Pickup ECT |
| CRK_ECT1 | Low ECT Boundary For Sequential Electronic Fuel Injection Fuel During Crank |
| FN384A | RPM To Exit Crank Mode |
| FN755 | Ignition Timing When Exiting Crank |
| CRK_SEFI_SW | Switch To Sequential Electronic Fuel Injection Fuel During Crank |
| FN385A | Underspeed To Run RPM |
| CRK_ECT2 | High Side ECT Boundary For Sequential Electronic Fuel Injection Fuel During Crank |
| FN024H | Xnorm Crank Fueling 02 |
| FN023T | Xnorm Crank Fueling 04 |
| FN020E | Ynorm Crank Fueling 02 |
| FN024T | Ynorm Crank Fuel 03 |
| Manufacturer Name | Name |
|---|---|
| K_CONV | K CONV |
| Manufacturer Name | Name |
|---|---|
| ACT_FMEM | ACT Cal If Sensor Is Determined Bad |
| ALT_CAL_DIST | ALT CAL DIST |
| BPMAX | Baro Pressure Level Max |
| BPMIN | Baro Pressure Level Min |
| MIL_SW | Check Engine Light Sw |
| XTALHPS | Clock Speed |
| P0054SW | Code P0054 Switch |
| P0060SW | Code P0060 Switch |
| P0068SW | Code P0068 Switch |
| P0103SW | Code P0103 Switch |
| P0108SW | Code P0108 Switch |
| P0128SW | Code P0128 Switch |
| P0138SW | Code P0138 Switch |
| P0141SW | Code P0141 Switch |
| P0148SW | Code P0148 Switch |
| P0148_LVL | Code P0148 Limit |
| P0155SW | Code P0155 Switch |
| P0158SW | Code P0158 Switch |
| P0161SW | Code P0161 Switch |
| P0171SW | Code P0171 Switch |
| P0172SW | Code P0172 Switch |
| P0174SW | Code P0174 Switch |
| P0175SW | Code P0175 Switch |
| P0190SW | Code P0190 Switch |
| P0191SW | Code P0191 Switch |
| P0192SW | Code P0192 Switch |
| P0193SW | Code P0193 Switch |
| P0201SW | Code P0201 Switch |
| P0202SW | Code P0202 Switch |
| P0203SW | Code P0203 Switch |
| P0204SW | Code P0204 Switch |
| P0205SW | Code P0205 Switch |
| P0206SW | Code P0206 Switch |
| P0207SW | Code P0207 Switch |
| P0208SW | Code P0208 Switch |
| P0209SW | Code P0209 Switch |
| P0210SW | Code P0210 Switch |
| P0232SW | Code P0232 Switch |
| P0300SW | Code P0300 Switch |
| P0301SW | Code P0301 Switch |
| P0302SW | Code P0302 Switch |
| P0303SW | Code P0303 Switch |
| P0304SW | Code P0304 Switch |
| P0305SW | Code P0305 Switch |
| P0306SW | Code P0306 Switch |
| P0307SW | Code P0307 Switch |
| P0308SW | Code P0308 Switch |
| P0315SW | Code P0315 Switch |
| P0316SW | Code P0316 Switch |
| P0340SW | Code P0340 Switch |
| P0401SW | Code P0401 Switch |
| P0402SW | Code P0402 Switch |
| P0403SW | Code P0403 Switch |
| P0405SW | Code P0405 Switch |
| P0406SW | Code P0406 Switch |
| P0420SW | Code P0420 Switch |
| P0430SW | Code P0430 Switch |
| P0442SW | Code P0442 Switch |
| P0443SW | Code P0443 Switch |
| P0446SW | Code P0446 Switch |
| P0452SW | Code P0452 Switch |
| P0453SW | Code P0453 Switch |
| P0454SW | Code P0454 Switch |
| P0455SW | Code P0455 Switch |
| P0456SW | Code P0456 Switch |
| P0457SW | Code P0457 Switch |
| P0460SW | Code P0460 Switch |
| P0461SW | Code P0461 Switch |
| P0462SW | Code P0462 Switch |
| P0463SW | Code P0463 Switch |
| P0480SW | Code P0480 Switch |
| P0481SW | Code P0481 Switch |
| P0500SW | Code P0500 Switch |
| P0602SW | Code P0602 Switch |
| P0605SW | Code P0605 Switch |
| P0606SW | Code P0606 Switch |
| P0707SW | Code P0707 Switch |
| P0708SW | Code P0708 Switch |
| P0713SW | Code P0713 Switch |
| P0722SW | Code P0722 Switch |
| P1000SW | Code P1000 Switch |
| P1233SW | Code P1233 Switch |
| P1237SW | Code P1237 Switch |
| P1260SW | Code P1260 Switch |
| P1270SW | Code P1270 Switch |
| P1502SW | Code P1502 Switch |
| P1633SW | Code P1633 Switch |
| P1635SW | Code P1635 Switch |
| P1639SW | Code P1639 Switch |
| P1702SW | Code P1702 Switch |
| P1703SW | Code P1703 Switch |
| P1705SW | Code P1705 Switch |
| P1711SW | Code P1711 Switch |
| P1729SW | Code P1729 Switch |
| P2008SW | Code P2008 Switch |
| P2014SW | Code P2014 Switch |
| P2096SW | Code P2096 Switch |
| P2097SW | Code P2097 Switch |
| P2098SW | Code P2098 Switch |
| P2099SW | Code P2099 Switch |
| P2195SW | Code P2195 Switch |
| P2197SW | Code P2197 Switch |
| SARCHG | Engine Displacement |
| VSS_ERR_LVL | Deviation Limit For P0500 |
| IMSC_CNT_LVL | Deviation Limit For P1519 |
| TCVSR | Filter For Vehicle Acceleration Rate Command |
| TCVST | Filter For VSS For Transmission |
| INJ_FAIL_CNT | Injector Fail Count Set High |
| EPTMAX | Max EPT Counts For Failure |
| EVPMAX | Max EVP Counts For Failure |
| OSS_ERR_UP | OSS Deviation Up Counter |
| P0112SW | P0112 SW |
| P0113SW | P0113 SW |
| PDL_EOW_LVL | P0708 Engine Off Limit |
| PDL_W_LVL | P0708 Engine Running Limit |
| PDL_W_UP | P0708 Up Counter |
| TRS_ERRW_UP | P0708 Up Counter 1 |
| PUL_PER_GAL | Pulses Per Gallon Conversion Factor |
| DISFMEM_DSRD | Sw To Take Fault Action On DIS Fault |
| MISFMEM_DSRD | Sw To Take Fault Action On Misifre |
| FMDTM | Duration Delay To Turn Check Engine Light |
| WOTCOT | Duration Inhibit AC At Wide Open Throttle |
| CHT_ER_TM | Duration For CHT Fault To Set Code |
| FNECTWUT | Duration For Warm Up |
| ACTP_SH | TP Above Inhibits AC At Wide Open Throttle |
| ACTP_CL | TP Below To Permit AC After Wide Open Throttle |
| DELTA | TP For PT |
| FN513 | TP For WOT |
| FN654S | Warm Up Duration |
| Manufacturer Name | Name |
|---|---|
| DFSRPM_PC | DFSRPM PC |
| DFLOD | Max Engine Load To Enter |
| DFS_PRV_N | Max RPM To Permit Hysteresis |
| DFSECT | Min Coolant For Fuel Shutoff |
| DFSECT_PC | Min Coolant For Fuel Shutoff In Profile Corr |
| DFNOVS | Min N/V Allowed For Fuel Shut Off |
| DFSRPM | Min RPM To Enter |
| DFSVS | Min VSS To Enter |
| NDFSO | Neutral Deceleration Fuel Shutoff Selection Flag |
| DFSRPM_CL | RPM Below To Turn Fuel On |
| DFS_PRV_SW | Switch To Permit Hysteresis |
| DFSO_PC_SW | Switch To Set To Zero |
| CTDFSO | Duration At Closed Throttle To Enter |
| CTEDSO | Duration At Closed Throttle To Enter Extended |
| TOUT_RMPOFF | Engine Torque Ramp Off Rate |
| TOUT_RMPON | Engine Torque Ramp On Rate |
| DFSVS_CL | VSS Below To Turn Fuel On |
| Manufacturer Name | Name |
|---|---|
| FP_EO_DM_SW | FP EO DM SW |
| FP_ER_DM_SW | FP ER DM SW |
| FP_PU_DM_SW | FP PU DM SW |
| VS_EDG_MILE | Pulses Per Mile Speedo |
| Manufacturer Name | Name |
|---|---|
| HESDETFR_CAL | Forced Anti Stall Fraction |
| FUL_IOM_CAL | Forced Maturity Cal |
| FUL_IOM_LMIN | Number Of Loops To Be Mature |
| FUL_IOM_SMIN | Min Switch Count For Learning Maturity |
| HESDET_SW | Switch To Shut Off Hes Detection |
| VSBAR_MIN | Max VSS For OSC |
| INJON_TST | Injectors On When Tq Test Sw Set |
| LAM_TST | Lambda When Tq Test Sw Set |
| SPK_TST | Ignition Timing Engine Torque Ratio When Tq Test Sw Set |
| Manufacturer Name | Name |
|---|---|
| MIS_NMAX_NEU | Max Misfire RPM Neutral |
| Manufacturer Name | Name |
|---|---|
| CCL_SW | Check Fuel Cap Switch |
| J1979_01_1C | Emissions Level For Vehicle |
| ENG_CONFIG_1 | Engine Configuration 1 |
| MODE08MAP_1 | Mode08 Mapping 1 |
| MODE08MAP_2 | Mode08 Mapping 2 |
| MODE08MAP_3 | Mode08 Mapping 3 |
| MODE08MAP_4 | Mode08 Mapping 4 |
| PIDMAP_1 | PIDMAP 1 |
| PIDMAP_2 | PIDMAP 2 |
| PIDMAP_3 | PIDMAP 3 |
| PIDMAP_4 | PIDMAP 4 |
| TESTIDMAP_1 | Testid Mapping 1 |
| TESTIDMAP_2 | Testid Mapping 2 |
| TESTIDMAP_3 | Testid Mapping 3 |
| TESTIDMAP_4 | Testid Mapping 4 |
| TESTIDMAP_5 | Testid Mapping 5 |
| TESTIDMAP_6 | Testid Mapping 6 |
| TESTIDMAP_7 | Testid Mapping 7 |
| Manufacturer Name | Name |
|---|---|
| BYPS_BRKPNT | BYPS BRKPNT |
| COIL_NMAX | COIL NMAX |
| COIL_VBATMAX | COIL VBATMAX |
| COIL_VBATMIN | COIL VBATMIN |
| CPRIMLVL | Coil Primary Voltage Lower Threshold |
| CPRIMUP | Coil Primary Voltage Upper Threshold |
| DIS_COP_HW | DIS COP HW |
| PIPERR | PIPERR |
| V_1PAC_ERR | V 1PAC ERR |
| VNREVIDM | VNREVIDM |
| Manufacturer Name | Name |
|---|---|
| VCIDSW | CID Test Switch |
| CIDUP | CID Up Counter |
| V_PIP_HARD | Max Duration Between PIPS For Fault |
| PIPLVLEXP | PIP Fault Filter |
| PIPUP | Profile Ignition Pickup Up Counter |
| Manufacturer Name | Name |
|---|---|
| FN908H | EGR Flow Rate Altitude |
| FN908G | EGR Flow Rate Sea Level |
| EGRMPT | EGR MPT |
| FN_EGR_WOT | EGR Multiplier For WOT |
| FN211 | EGR Multiplier With Coolant Temperature |
| FN220 | EGR Multiplier With Inlet Air Temperature |
| FN220A | EGR Multiplier With Outside Temperature |
| EGRDC_MAX | Max EGR Duty Cycle |
| FN248C | Max EGR Flow Rate |
| MINDES_CL | Min Air Flow For EGR Disable |
| MINDES_SH | Min Air Flow For EGR Enable |
| EGR_TP_MIN | Min Throttle For EGT |
| FN230A | Duration Delay To Begin EGR |
| FN070 | Xnorm EGR 05 |
| FN071 | Ynorm EGR 04 |
| Manufacturer Name | Name |
|---|---|
| PG_CATMID_CL | Cat Temperature For Purge Hysteresis |
| FN610 | FTPT Transfer Relationship |
| PG_CATMID_SH | Min Cat Temperature For Purge |
| PG_OL_START | Open Loop Purge Delay |
| PG_DFS_TM | Duration To Hold Purge When Cylinders Are Shut Off |
| Manufacturer Name | Name |
|---|---|
| AIR_BRK_IAF | Air Leakage From Brake Booster |
| ARCHLK | Unmetered Air Leakage |
| Manufacturer Name | Name |
|---|---|
| FN441D | BP Effect On Exhaust Temperature |
| FNEXOMF | Cat Exotherm Due To Misfire |
| FNFL_EXT | Exhaust Flange Temperature |
| LAM_1ST_STEP | Lambda 1st Step In Control |
| LAM_EXT_MAX | Lambda Absoute Value Used For Starting Control |
| FN_EXT_STP | Lambda Decrement For Temperature Difference |
| LAM_EXT_STEP | Lambda Decrement When In Temperature Control Per 40ms |
| FN441A__A | Lambda Effect On Exhaust Temp |
| LAM_EXT_LBT | Lambda Exhaust Temperature LBT |
| LAM_AVE_SW | Lambda Switch For Absolute Or Step Control |
| LAM_EXT_MIN | Lowest Lambda Cal Allowed For Temperature Control |
| FN441B | Spark Effect On Exhaust Temp |
| TC_SOAK_FL | TC SOAK FL |
| FN445L | Temperature Loss From Manifold To Catalyst |
| FN443L | Temperature Loss From Manifold To O2 Sensor |
| FN442__A | Duration Constant For Exhaust Temperature |
| FN443 | Duration Constant For O2 Sensor Temperature |
| FNFL_NRM_X | Xnorm Exhaust Temperature 18 |
| FNFL_NRM_Y | Ynorm Exhaust Temperature 18 |
| Manufacturer Name | Name |
|---|---|
| COOL_CHT_MAX | CHT Temperature That Defines Stage 2 |
| CHT_CRIT_SH | CHT Temperature That Defines Stage 3 |
| CHTIL_MAX | CHT Temperature To Turn On Light Stage 1 |
| COOL_CYL_OFF | Cylinders To Shut Off In Stage 3 |
| COOL_INT | Failsafe Cooling Integral Gain Cal |
| COOL_GN | Failsafe Cooling Overall Gain Cal |
| COOL_CYL_MIN | Min Cylinders To Shut Off |
| COOL_CYL_IDL | Min Cylinders To Shut Off At Idle |
| FNCOOL_MAX | Number Of Cylinders To Turn Off |
| COOL_CAL_SW | Switch To Permit Failsafe Cooling |
| COOL_MAN | Switch To Force Manual Failsage Cooling |
| COOL_WOT_TIM | Duration To Keep All Cylinders On At Wide Open Throttle |
| Manufacturer Name | Name |
|---|---|
| FIECT_3_CL | ECT Inhibits Oil Overtemp Mode |
| FIECT_3_SH | ECT To Permit Oil Overtemp Mode |
| FIRPM_3 | RPM To Permit Oil Overtemp Mode |
| FILOAD_3 | Engine Load To Permit Oil Overtemp Mode |
| FITP_3 | Throttle To Permit Oil Overtemp Mode |
| FNTOIL_ECT | Engine Torque Ratio Vs ECT |
| FNTOIL_RPM | Engine Torque Ratio Vs RPM |
| Manufacturer Name | Name |
|---|---|
| FFS_SW | Flex Fuel Sensor Switch |
| Manufacturer Name | Name |
|---|---|
| FN1362LX | Base Fuel Table Cold |
| FN1361X_LOST | Base Fuel Table Cold Enrichment Decay Lost Time |
| FN1361X | Base Fuel Table Cold Enrichment Decay Time |
| FN1361L | Base Fuel Table Enleanment When Cold |
| FN018C | Ynorm Startup Cold Fuel 07 |
| Manufacturer Name | Name |
|---|---|
| FN393F | A/f Enrichment For Engagements Duration Forward |
| FN393R | A/f Enrichment For Engagements Duration Reverse |
| FN387X | A/f Multiplier To Avoid Stalls |
| WOTADP_SW | Adaptation Wide Open Throttle Sw |
| FN371 | Air Fuel Enrichment For Engagements |
| FKARCIDLE | Aircharge Filter For Idle |
| ANTICIPATION | Aircharge Switch For Anticipation Logic |
| ARCHSW | Aircharge Switch For Filtering |
| ARCHIDLE_SW | Aircharge Switch For Unique Idle Filter |
| ARCWOTCOR | Aircharge Wide Open Throttle Multiplier |
| FNCYL_OFF__A | Commanded Lambda When Cyl Off |
| FUL_OVRD_LAM | Commanded Lambda When Fueling Is Overridden |
| ARCANTCOR | Compensation For Max Cylinder Air Charge |
| ECTSTABL_CL | ECT To Return To Base Fueling Table Cold |
| ECTSTABL | ECT To Switch Base Table |
| FUL_OVRD_SW | Fuel Override Switch |
| ECTSTABLTIM | Fuel Duration To Switch Base Table |
| LAM_CYL_OFF | Lambda When Cylinders Are Off |
| LOST_FUL_ADD | Lost Fueling Adder |
| LOST_FUL_MUL | Lost Fueling Multiplier |
| AIR_MAN_VOL | Manifold Volume (liters) |
| OLMCL | Non Feedback Fuel Multiplier |
| PRLDSW | Percent Load Switch |
| EXT_CMD_SF | Safety Factor To Adjust Max Cat Temperature |
| EXT_FLN_SF | Safety Factor To Adjust Max Flange Temperature |
| EXT_FEGO_SF | Safety Factor To Adjust Max HEGO Temperature |
| NOMINAL_AFR | Stoichiometric Air Fueling Ratio |
| CAT_TEMP_SW | Switch For Cat Temperature Ctl |
| FEG_TEMP_SW | Switch For Ego Temperature Ctl |
| FLN_TEMP_SW | Switch For Flange Temperature Ctl |
| FUL_CTRL_SW | Switch Identifies Fuel Control Mode |
| CAT_MAX_LO | Temperature To Begin Fuel Control For Cats Stage1 |
| CAT_MAX_HI | Temperature To Begin Fuel Control For Cats Stage2 |
| FEGO_MAX | Temperature To Begin Fuel Control For Ego |
| FLN_MAX | Temperature To Begin Fuel Control For Flange Stage2 |
| CAT_MAX_CL | Temperature To Exit Fuel Control For Cats |
| FEGO_MAX_CL | Temperature To Exit Fuel Control For Ego |
| FLN_MAX_CL | Temperature Toexit Fuel Control For Flange |
| FN070C | Xnorm Fueling 21 |
| FN034A | Ynorm Fueling 20 |
| Manufacturer Name | Name |
|---|---|
| FN1360B | Base Fueling Table |
| FN1362X_LOST | Base Fuel Table Enrichment Lost Load |
| FN070B | Xnorm Base Fueling Calculation 22 |
| FN022BX | Xnorm Base Fuel Calculation 07 |
| FN072T | Ynorm Base Fueling Calculation 21 |
| FN072 | Ynorm Crank Fueling 03 |
| Manufacturer Name | Name |
|---|---|
| LAM_HOT_MIN | Min Allowed Short Term Fuel Trim With Lean Deviation |
| LAM_CHK_MAX | Short Term Fuel Trim Inhibits Logic |
| FUEL_ERR_SW | Switch Allowed For Use Of Plugged Filter Logic |
| OL_HOT_TM | Duration Between Checks For Lean Deviation |
| P0148_TC | Duration Constant For Lean Deviation |
| BYPLES1 | Duration Delay Period For Lack Of Switching |
| Manufacturer Name | Name |
|---|---|
| FN212A | Open Loop A/F Mult BP Lugging Sea Level |
| Manufacturer Name | Name |
|---|---|
| FN1347 | Engine Off Soak Duration Enrichment For Injectors |
| FNPWCOM_BK | Fuel Inj Breakpoint Multiplier FordeltaP |
| FNPWCOM_HS | Fuel Inj High Slope Multiplier FordeltaP |
| FNPWCOM_LS | Fuel Inj Low Slope Multiplier FordeltaP |
| FNPWCOM_OFF | Fuel Inj Offset Multiplier FordeltaP |
| FUEL_BRKPT | Fuel Injector Breakpoint |
| AHISL | Fueling Injector Hi Slope |
| ALOSL | Fueling Injector Low Slope |
| MINPW | Fuel Injector Lower Pulse Width |
| RF_DPREF_CAL | Fuel Injector Pressure Level Drop |
| FN367W | Injector Comp Batt Volt |
| INJ_PW_COMP | Injector Comp For Pressure |
| FN1338 | Injector Enrichement When Hot |
| FN1348 | Duration Since Running For Injector Enrichement |
| FN001 | Xnorm Fueling Injector 23 |
| FN008B | Xnorm Fueling Injector 24 |
| FN008 | Xnorm Fueling Injector 25 |
| FN001A | Ynorm Fueling Injector 25 |
| FN001B | Ynorm Fueling Injector 26 |
| FN007 | Ynorm Fueling Injector 27 |
| Manufacturer Name | Name |
|---|---|
| FN336 | Injector Timing Vs ECT |
| INTAKE_OPEN | Intake Valve Opening Degrees |
| SPRAY_DELAY | Duration For Fuel Travel To Valve |
| Manufacturer Name | Name |
|---|---|
| FP_CRK_SW | FP CRK SW |
| FP_DRIVER | Fuel Pump Driver Type |
| FPMP_ON_TM | Fuel Pump Min On Duration |
| FP_EO_DT_SW | P0230 Switch For KOEO Test |
| FP_ER_DT_SW | P0230 Switch For KOER Test |
| FP_PU_DT_SW | P0230 Switch For Power Up |
| FPMP_OSM_ENA | P0230 Switch When Running |
| FP_EO_ST_SW | P0231 Switch For KOEO Test |
| FP_ER_ST_SW | P0231 Switch For KOER Test |
| FP_PU_ST_SW | P0231 Switch For Power Up |
| FPMP_SMON_EN | P0231 Switch When Running |
| Manufacturer Name | Name |
|---|---|
| FP_PU_TM | 2speed Fuel Pump Minimum On Duration |
| Manufacturer Name | Name |
|---|---|
| GRRAT1 | 1st Gear Ratio |
| GRRAT2 | 2nd Gear Ratio |
| GRRAT3 | 3rd Gear Ratio |
| GRRAT4 | 4th Gear Ratio |
| NVBASE | Base N/V Of Vehicle |
| RT_CHAIN | Chain Ratio |
| NOV_MAX | Max Learned N/V |
| NOV_MIN | Min Learned N/V |
| NOVCNT | Multiplier NV |
| Manufacturer Name | Name |
|---|---|
| RT_FIRST_GR | 1st Gear Ratio Manual |
| RT_SECOND_GR | 2nd Gear Ratio Manual |
| RT_THIRD_GR | 3rd Gear Ratio Manual |
| RT_FOURTH_GR | 4th Gear Ratio Manual |
| RT_FIFTH_GR | 5th Gear Ratio Manual |
| Manufacturer Name | Name |
|---|---|
| FN503 | Imrc Opening Rpm |
| IMRC_TWOPOSN | Imrc Two Position Sensor Switches |
| Manufacturer Name | Name |
|---|---|
| FN894 | Dashpot Limit 1 |
| FN894H | Dashpot Limit 4th Gear |
| FN894L | Dashpot Limit W/O Deceleration 4th Gear |
| FN879 | Dashpot Decay Rate |
| DASCTL | Dashpot For Zeroing Entry Timer |
| DASCLP_4INH | Dashpot Inhibit 4th Gear |
| FN882A | Dashpot Max Clip RPM |
| FN891 | Dashpot Max Clip VS |
| DASMPH | Dashpot Min Mph |
| FN830 | Dashpot Preposition |
| SETLNG_TM | Dashpot Settling Duration |
| DASMHYST | Dashpot Hysteresis Band |
| DASPTK | Isc Dashpot Gain |
| LOWLOD | Min Engine Load Seen For Idle |
| TCDASD | Dashpot Decay Time Constant |
| TCDASU | Dashpot Recovery Time Constant |
| Manufacturer Name | Name |
|---|---|
| FN894HLC | Dashpot Clip 4th Gear W/locked Torque Converter |
| FN894LLC | Dashpot Clip W/no Decel 4th Gear Lk'd Converter |
| FN879LC | Dashpot Decay Rate W/locked Torque Converter |
| Manufacturer Name | Name |
|---|---|
| EDFPPM | Air Adder When Fan Is On |
| FN819 | Air Flow From Not Measured By MAF |
| FN818 | Air Flow From PCV Not Measured By MAF |
| ITHBMA | Air Flow Through Throttle Body |
| IFBS_RPM_TC | Desried RPM Duration Constant |
| DSDRPM_OFF | DSDRPM OFF |
| FN394F_TEH | ECT Dependent Dly For N D Engagement |
| FN394R_TEH | ECT Dependent Dly For N R Engagement |
| TCTRAN_RPM | Filter For Recognizing N D/R Engagement |
| FN851A | Gn For Idle Ctrl Err Deriv Ctl RPM Err |
| FN852A | Gn For Idle Ctrl Err Prop Ctl |
| HEDFRPM | HEDFRPM |
| FN822 | Idle Air Adder For Powersteering Switch |
| FN1886 | Idle Air Adder For Ps Transducer |
| IS_DRBASE | Idle Speed Drive |
| IS_DRBASE_A | Idle Speed Drive Alt |
| IS_NUBASE | Idle Speed Neutral |
| IS_NUBASE_A | Idle Speed Neutral Alt |
| FN825B | Idle VSS RPM Adder For ACT |
| FN825A | Idle Speed RPM Adder For ECT |
| FN880N | Idle VSS RPM Using Duration Neutral |
| FN875HD | Isc Drive Idle Air |
| IDCOFS | Isc Duty Cycle Adder |
| IDCMUL | Isc Duty Cycle Multiplier |
| FN875HN | Isc Neutral Idle Air |
| ISC_PTP | Isc Peak To Peak |
| ISC_PTP_SW | Isc Peak To Peak Switch |
| FN8000 | ISC Valve Transfer Function |
| IPSIMAX | Max Air Integrator While Moving |
| IDLMAF | Max Air Mass Allowed At |
| ISCLPD | Max Allowed Idle Speed Drive |
| PSIBRM | Max Value Used For Idle Integrator |
| VSCLP | Max VSS For Feedback Idle |
| FN861 | Min Idle VSS Drive Using TOT |
| FN861R | Min Idle VSS Reverse Using TOT |
| MINMPH | Min Mph For Idle |
| PSIBRN | Min Value Used For Idle Integrator |
| RPMCTL | RPM Deviation From Requested To Begin Idle Control |
| RPMDED | RPM Deviation From Requested To Not Allow Adaptation |
| IS_GPAS_TC | Duration Constant Dsd RPM Neutral Hi Cam |
| TCDESN | Duration Constant Dsd RPM When At Limit |
| TC_OVER | Duration Constant For Air Integrator Above |
| TC_UNDER | Duration Constant For Air Integrator Below |
| NDDELTA | Duration Delay Period For N D Transition |
| UPDISC | Duration Dly Before Adaptation Is Allowed |
| EDF_DELAY | Duration To Delay Air Adder When Fan Is On |
| UPDATM | Update Rate Command |
| FN084 | Xnorm Idle 13 |
| FN061 | Xnorm Idle 14 |
| FN089 | Ynorm Idle 24 |
| FN060 | Ynorm Idle 14 |
| Manufacturer Name | Name |
|---|---|
| FNACC_DELAY2 | AC Air Compensation Delay Cycling |
| FNACC_DELAY | AC Air Compensation Delay Initial |
| FNIDLCOT2 | AC Compressor Delay Period Cycling |
| FNIDLCOT | AC Compressor Delay Period Starting |
| FN881 | Idle Air Adder For A/C Using Head Pressure Level |
| FN887 | Idle Air Adder For A/C W ACT |
| FN885 | Idle Air Adder For A/C W RPM |
| FN885TE | Idle Air Adder Timer W RPM |
| DNAC_DR | Idle VSS Adder With A/C On In Drive |
| DNAC_NEUT | Idle VSS Adder With A/C On In Neutral |
| Manufacturer Name | Name |
|---|---|
| AIR_BRK_DCY | AIR BRK DCY |
| AIR_BRK_DUR | AIR BRK DUR |
| AIR_BRK_IAF | AIR BRK IAF |
| AIR_BRK_SW | AIR BRK SW |
| AIR_BRK_VS | AIR BRK VSS |
| Manufacturer Name | Name |
|---|---|
| FN1301E | Targeted RPM |
| FN032EX | Xnorm Hes Det 25 |
| FN032EY | Ynorm Hes Det 26 |
| Manufacturer Name | Name |
|---|---|
| FN1862D | Air Flow Multiplier In Drive |
| FN1862N | Air Flow Multiplier In Neutral |
| BZZRPM | Idle VSS Adder For Startup |
| BZZTM | Idle VSS Adder For Startup Max Duration |
| FN826B | Idle VSS RPM Adder For ACT At Startup |
| FN826A | Idle VSS RPM Adder For ECT At Startup |
| TKDTN | Duration To Keep Adder For Startup ACT |
| FN803A | Duration To Keep Adder For Startup ECT |
| FN020C | Xnorm Startup 13 |
| FN018B | Ynorm Alcohol 25 |
| Manufacturer Name | Name |
|---|---|
| KNK_FAST_CNT | Cyl Events After Engine Load Trans For Knk Det Fst Counter |
| FAST_SPK_ADV | Fast Ignition Timing Advance Increment |
| KNK_GLOBAL | Global Or Individual Cylinder Switch |
| KNK_EVCNT | Knk Events For Fast Adv Mode |
| FN1135B | Knock Sensor Advance Limit |
| FN146D | Knock Sensor Advance Rate Command |
| FN146E | Knock Sensor Fast Advance Rate Command |
| KNK_MAX_RPM | Knock Sensor Max RPM |
| KNK_MIN_ECT | Knock Sensor Min ECT |
| KNK_MIN_LOAD | Knock Sensor Min Engine Load |
| KNK_MIN_RPM | Knock Sensor Min RPM |
| KI_MODE | Knock Sensor Mode Switch |
| FN1148A | Knock Sensor Retard |
| FN143B | Knock Sensor Retard Rate Command |
| CYL_1_SENS | Knock Sensor To Use For Cyl 1 |
| CYL_10_SENS | Knock Sensor To Use For Cyl 10 |
| CYL_2_SENS | Knock Sensor To Use For Cyl 2 |
| CYL_3_SENS | Knock Sensor To Use For Cyl 3 |
| CYL_4_SENS | Knock Sensor To Use For Cyl 4 |
| CYL_5_SENS | Knock Sensor To Use For Cyl 5 |
| CYL_6_SENS | Knock Sensor To Use For Cyl 6 |
| CYL_7_SENS | Knock Sensor To Use For Cyl 7 |
| CYL_8_SENS | Knock Sensor To Use For Cyl 8 |
| CYL_9_SENS | Knock Sensor To Use For Cyl 9 |
| KNK_SNS_TYPE | Knock Sensor Type |
| UP_NORM_EC | Knock Duration Constant When Up Averaging |
| FN775 | Limit Multiplier For ACT |
| FN776 | Limit Multiplier For ECT |
| FN070U | Xnorm Knock Sensor 28 |
| FN071U | Ynorm Knock Sensor 29 |
| Manufacturer Name | Name |
|---|---|
| DN_NORM_EC | Constant For Down Averaging |
| UP_FAST_EC | Constant For Up Averageing During Transient |
| Manufacturer Name | Name |
|---|---|
| KNK_GN_ADD1 | Knock Sensor Gain Adder Snsr #1 |
| KNK_GN_ADD2 | Knock Sensor Gain Adder Snsr #2 |
| FN2900A | Knock Sensor Gain Sensor #1 |
| FN2901A | Knock Sensor Gain Sensor #2 |
| FN2911A | Knock Sensor Thers Cyl 1 |
| KNK_TH_ADD1 | Knock Sensor Thres Adder Cyl 1 |
| KNK_TH_ADD10 | Knock Sensor Thres Adder Cyl 10 |
| KNK_TH_ADD2 | Knock Sensor Thres Adder Cyl 2 |
| KNK_TH_ADD3 | Knock Sensor Thres Adder Cyl 3 |
| KNK_TH_ADD4 | Knock Sensor Thres Adder Cyl 4 |
| KNK_TH_ADD5 | Knock Sensor Thres Adder Cyl 5 |
| KNK_TH_ADD6 | Knock Sensor Thres Adder Cyl 6 |
| KNK_TH_ADD7 | Knock Sensor Thres Adder Cyl 7 |
| KNK_TH_ADD8 | Knock Sensor Thres Adder Cyl 8 |
| KNK_TH_ADD9 | Knock Sensor Thres Adder Cyl 9 |
| FN2910A | Knock Sensor Thres Cyl 0 |
| FN2912A | Knock Sensor Thres Cyl 2 |
| FN2913A | Knock Sensor Thres Cyl 3 |
| FN2914A | Knock Sensor Thres Cyl 4 |
| FN2915A | Knock Sensor Thres Cyl 5 |
| FN2916A | Knock Sensor Thres Cyl 6 |
| FN2917A | Knock Sensor Thres Cyl 7 |
| FN2918A | Knock Sensor Thres Cyl 8 |
| FN2919A | Knock Sensor Thres Cyl 9 |
| KNK_TH_MUL1 | Knock Sensor Thres Mult Cyl 1 |
| KNK_TH_MUL10 | Knock Sensor Thres Mult Cyl 10 |
| KNK_TH_MUL2 | Knock Sensor Thres Mult Cyl 2 |
| KNK_TH_MUL3 | Knock Sensor Thres Mult Cyl 3 |
| KNK_TH_MUL4 | Knock Sensor Thres Mult Cyl 4 |
| KNK_TH_MUL5 | Knock Sensor Thres Mult Cyl 5 |
| KNK_TH_MUL6 | Knock Sensor Thres Mult Cyl 6 |
| KNK_TH_MUL7 | Knock Sensor Thres Mult Cyl 7 |
| KNK_TH_MUL8 | Knock Sensor Thres Mult Cyl 8 |
| KNK_TH_MUL9 | Knock Sensor Thres Mult Cyl 9 |
| FN1140A | Knock Window Duration |
| KNKWIN_LEN | Knock Window Duration |
| FN1141 | Knock Window Bias |
| KNKWIN_START | Knock Window Bias 1 |
| Manufacturer Name | Name |
|---|---|
| ACDC_SW | ACDC Switch |
| AIR_ADAPT | Air Meter Adaption Switch |
| FN052BF | Backflow Entry TP |
| FN052BFLS | Backflow Entry TP Low Throttle |
| F | BP Modifier 1 |
| F | BP Modifier 2 |
| BAPFMM | Default Barometric Pressure Cal |
| FN1036A | Engine Load W/Failed MAF |
| FN1036B | Engine Load W/Failed MAF W/IMRC Open |
| MAF_HI_KOER | MAF Upper AD Counts For KOER |
| MAF_LO_KOER | MAF Upper AD Counts For KOER 1 |
| MAF_LO_ER | MAF Lower AD Counts |
| FN1023B | MAF Temp Compensation |
| FN036M | Maf Transfer Function |
| AIR_DEC_MUL | Manifold Dynamics Filter For Deceleration |
| MAF_HI_ER | Upper AD Counts |
| VMAFPIPLMT | Pip Limit For Over Voltage Level Conditon |
| MAF_RPM_MAX2 | RPM To Set Failed MAF |
| LOW_TP_SW | Switch To Use Low Throttle Backflow |
| P0103_LVL | Theshold For Over Voltage Level Conditon |
| TP_VMAF | TPS To Set Failed MAF |
| P0103_TC | Duration At Overvoltage To Be Failed |
| FN050 | Xnorm MAF 29 |
| FN070E | Xnorm MAF 30 |
| FN022Y | Ynorm MAF 30 |
| FN044 | Ynorm MAF 31 |
| Manufacturer Name | Name |
|---|---|
| ACBIAS | Bias When AC Is On |
| FN1353A | Closed Loop Bias |
| FN1353E1 | Feedback Bias Bank1 |
| FN1353E2 | Feedback Bias Bank2 |
| FN315 | Closed Loop Bias Multiplier W/VS |
| FNEGO_SWPT_1 | Front EGO Switch Point Relative To Stoichiometric Air Fuel |
| FN_USHTR_DC | Front O2 Heater Duty Cycle |
| FN_BAT_DCCMP | Front O2 Heater Duty Cycle Batt Mult |
| USHTRDC_SW | Front O2 Heater Duty Cycle Switch |
| US_HTR_ON | Front O2 On |
| HEATER_HP11 | Heater Switch For Bank1 Sensor1 O2 |
| HEATER_HP21 | Heater Switch For Bank2 Sensor1 O2 |
| FNFLO | HEGO Tip Temperature Change |
| TD_ADTOL | Magnitude Of Single Pass For Update |
| HTR_VOLT_NOM | Nominal O2 Heater Voltage Level |
| NUMEGO | Number Of O2 Sensors |
| ADAP_TD_SKIP | Number Of O2 Switches Before Adaptation |
| FNTDSEC8X10 | O2 Transport Delay Period In Seconds |
| TD_LOADMAX | O2 Transport Delay Period Max Engine Load Adapt |
| TD_NMAX | O2 Transport Delay Period Max RPM Adapt |
| TD_SEC_MAX | O2 Transport Delay Period Max Sec Adapt |
| TD_HEGO_MX | O2 Transport Delay Period Max Duration |
| TD_ECT_MIN | O2 Transport Delay Period Min Ect Adapt |
| TD_LOADMIN | O2 Transport Delay Period Min Engine Load Adapt |
| TD_NMIN | O2 Transport Delay Period Min RPM Adapt |
| TD_SEC_MIN | O2 Transport Delay Period Min Sec Adapt |
| TD_HEGO_MN | O2 Transport Delay Period Min Duration |
| TD_PTP_TOL | Peak To Peak Tolerance Limit |
| EGO_KOER_SW | Primary O2 Sensor Test Switch 3 |
| US_HTR_WARM | Temperature At Which Front O2 Is Warm |
| FN039E | Xnorm O2 Sensor 32 |
| FNFLO_NRM_X | Xnorm O2 Sensor 33 |
| FNFLO_NRM_Y | Ynorm O2 Sensor 33 |
| Manufacturer Name | Name |
|---|---|
| CAT1_FL_RAT | Bank1 Fault Ratio |
| CAT2_FL_RAT | Bank2 Fault Ratio |
| FEGO1_MX_TOT | Bank 1 Front Oxygen Sensor Max Switch Count |
| FEGO1_MX_CT1 | Bnk1 Max Frnt Hego Switches For AM Cell 1 |
| FEGO1_MX_CT2 | Bnk1 Max Frnt Hego Switches For AM Cell 2 |
| FEGO1_MX_CT3 | Bnk1 Max Frnt Hego Switches For AM Cell 3 |
| FEGO2_MX_TOT | Bank 2 Front Oxygen Sensor Max Switch Count |
| FEGO2_MX_CT1 | Bnk2 Max Frnt Hego Switches For AM Cell 1 |
| FEGO2_MX_CT2 | Bnk2 Max Frnt Hego Switches For AM Cell 2 |
| FEGO2_MX_CT3 | Bnk2 Max Frnt Hego Switches For AM Cell 3 |
| OBD2_FUL_LVL | Low Fuel Limit |
| CAT_ACT_MAX | Max Allowed ACT To Run Cat Monitor |
| AM1_MAX | Max Allowed Air Mass For Cell 1 In Cat Monitor |
| AM2_MAX | Max Allowed Air Mass For Cell 2 In Cat Monitor |
| AM3_MAX | Max Allowed Air Mass For Cell 3 In Cat Monitor |
| CAT_ECT_MAX | Max Allowed ECT To Run Cat Monitor |
| CAT_EGRMAX | Max Allowed EGR To Run Cat Monitor |
| CAT_LD_MAX1 | Max Allowed Load To Run Cat Monitor Cell 1 |
| CAT_LD_MAX2 | Max Allowed Load To Run Cat Monitor Cell 2 |
| CAT_LD_MAX3 | Max Allowed Load To Run Cat Monitor Cell 3 |
| CAT_N_MAX1 | Max Allowed RPM To Run Cat Monitor Cell 1 |
| CAT_N_MAX2 | Max Allowed RPM To Run Cat Monitor Cell 2 |
| CAT_N_MAX3 | Max Allowed RPM To Run Cat Monitor Cell 3 |
| CAT_VSMAX | Max Allowed Vechile VSS To Run Cat Monitor |
| CAT_MX_LEAN | Max Cat Midbed Temperature To Run Cat Monitor |
| MIDBED_MAX1 | Max Cat Midbed Temperature To Run Cat Monitor Cell 1 |
| MIDBED_MAX2 | Max Cat Midbed Temperature To Run Cat Monitor Cell 2 |
| MIDBED_MAX3 | Max Cat Midbed Temperature To Run Cat Monitor Cell 3 |
| CAT_TP_MAX | Max TP Rate For Cat |
| CAT_ACT_MIN | Min Allowed ACT To Run Cat Monitor |
| AM1_MIN | Min Allowed Air Mass For Cell 1 In Cat Monitor |
| AM2_MIN | Min Allowed Air Mass For Cell 2 In Cat Monitor |
| AM3_MIN | Min Allowed Air Mass For Cell 3 In Cat Monitor |
| CAT_ECT_MIN | Min Allowed ECT To Run Cat Monitor |
| CAT_EGRMIN | Min Allowed EGR To Run Cat Monitor |
| CAT_LD_MIN1 | Min Allowed Load To Run Cat Monitor Cell 1 |
| CAT_LD_MIN2 | Min Allowed Load To Run Cat Monitor Cell 2 |
| CAT_LD_MIN3 | Min Allowed Load To Run Cat Monitor Cell 3 |
| CAT_N_MIN1 | Min Allowed RPM To Run Cat Monitor Cell 1 |
| CAT_N_MIN2 | Min Allowed RPM To Run Cat Monitor Cell 2 |
| CAT_N_MIN3 | Min Allowed RPM To Run Cat Monitor Cell 3 |
| CAT_VSMIN | Min Allowed Vechile VSS To Run Cat Monitor |
| MIDBED_MIN1 | Min Cat Midbed Temperature To Run Cat Monitor Cell 1 |
| MIDBED_MIN2 | Min Cat Midbed Temperature To Run Cat Monitor Cell 2 |
| MIDBED_MIN3 | Min Cat Midbed Temperature To Run Cat Monitor Cell 3 |
| CAT_REG_TEMP | Min Rear O2 Temperature To Run Cat Monitor |
| CAT_APT_FLG | Switch Allowed For Closed Throttle Counting |
| CAT_STBLE_TM | Duration For Cat To Stabilize |
| Manufacturer Name | Name |
|---|---|
| OBD_VBAT_MAX | Max Battery Volt To Run Test |
| IS_TCC_DCMX | Max TCC DC To Turn Off Inductive Sig |
| FNMAXISIGTOT | Max Tot For ISIG Test Vbat |
| TVP_ISIG_MAX | Max TV To Turn Off Inductive Sig |
| OBD_VBAT_MIN | Min Battery Volt To Run Test |
| MN_RT_TOT | Min Tot For Ratio Test |
| OBDII_MIL_SW | Obdii MIL Switch |
| OBDII_TST_SW | Obdii Test Switch |
| MIL_ODO_SW | Switch To Turn Off Distance Traveled Calc |
| SS1_IS_SW | Switch To Turn Off Inductive Sig Ss1 |
| SS2_IS_SW | Switch To Turn Off Inductive Sig Ss2 |
| TCC_IS_SW | Switch To Turn Off Inductive Sig TCC |
| Manufacturer Name | Name |
|---|---|
| CCM_MIN_AMB | CCM Min Ambient To Run |
| CCM_MIN_SOAK | CCM Min Soak Duration |
| CCM_MON_TM | CCM Monitor Duration |
| Manufacturer Name | Name |
|---|---|
| DS_HEAT_TM | DS HEAT TM |
| LEAN_THRESH | LEAN THRESH |
| N_IDLE_CH | N IDLE CH |
| N_IDLE_SL | N IDLE SL |
| RICH_THRESH | RICH THRESH |
| TC_VEGO_FA | TC VEGO FA |
| Manufacturer Name | Name |
|---|---|
| FN1405_THRES | Delta P Limit For Setting P1405 |
| FN1406_THRES | Delta P Limit For Setting P1406 |
| EGR_402_AM | EGR 402 AM |
| EGR_402_INC | EGR 402 INC |
| EGR_402_MAX | EGR 402 MAX |
| EGRMON_TM | EGR Monitor Completion Duration Out |
| EGR_WRM_TM | EGR Monitor Warm Up Offset Duration |
| EPT_VOPN_IDL | EGR Valve Position At Engine Off |
| XFREPT | EPT Transfer Function |
| EPTZER_VALID | EPTZER VALID |
| PE_OBD_THRES | Exhaust Pressure Limit For EGR Tests |
| IXFRPR | Inverse EPT Transfer Function |
| EGR_MON_ACTH | Max ACT For EGR Monitor |
| EGR_HT_AM_MX | Max Air Flow For Hose Test |
| EGR_WOTAM_MX | Max Air Mass For EGR Tests |
| DELARCH_EGR | Max Change In Air Change For EGR Tests |
| EPTMAX | Max Counts For EPT Sensor |
| EGR_OBD_NMAX | Max Engine Speed For EGR OBDII Tests |
| EGR_MON_ACTL | Min ACT For EGR Monitor |
| EGR_MIN_AMB | Min Ambient Temperature To Run EGR Monitor |
| BP_EGRMON | Min BP To Run EGR Monitor |
| EPTMIN | Min Counts For EPT Sensor |
| FN202 | Min Delta P For Sys Pressure High DC |
| EGR_VLV_OPN | Min Duration For EGR To Be Open For Test |
| EGR_VLV_SHT | Min Duration For EGR To Be Shut For Test |
| MIN_MVAC | Min Vacuum To Run EGR Test |
| EGR_TCL_TRIP | Number Of Trips To Complete Monitor |
| P401_TST_TM | P0401 Test Duration |
| P0402TST_TM | P0402 Test Duration |
| P0403TST_TM | P0403 Test Duration |
| P0405TST_TM | P0405 Test Duration |
| P0406TST_TM | P0406 Test Duration |
| P1405TST_TM | P1405 Test Duration |
| P1406TST_TM | P1406 Test Duration |
| P1408TST_TM | P1408 Test Duration |
| Manufacturer Name | Name |
|---|---|
| CVS_FALT_CNT | Canister Vent Solenoid Limit For P1451 |
| CANV_THRES | Canister Vent Limit For P1451 |
| FN610A_SCP | Fueling Level To % Fueling W/O Saddle Tank |
| PGM_IDACT_MX | Max Air Temperature For Idle Soak Test |
| PGM_PPM_TSTX | Max Flow In Ph0 To Enter Ph1 |
| PGM_TEMP_MAX | Max For Temperature Test |
| PGM_FLI_MAX | Max Fuel Level For Test |
| PGM_ID_LAMX | Max Lambda For Purge |
| PGM_LOAD_MAX | Max Engine Load For Purge Test |
| PGM_RST_CNT | Max Number Of Purge Monitor Tries Per Key On |
| PGM_P0_WMXI | Max Purge Flow For Idle Test |
| PGM_PS0_HI | Max Tank Press For Ph0 Deadband |
| FN_TP_DT_MXI | Max Tank Pressure Level Change To Abort Idle Test |
| FN_TP_DT_MX | Max Tank Pressure Level Change To Abort Test |
| PGM_TANK_MAX | Max Tank Pressure Level For Test |
| PGM_VAP_LIM | Max Tank Prs Change To Go From Ph4 To Ph5 |
| PGM_VAP_MAX | Max Tank Prs To Go From Ph4 To Ph5 |
| PGM_IDACT_MN | Min Air Temperature For Idle Soak Test |
| PGM_BP_MIN | Min Barometric Pressure For Purge Monitor |
| PGM_TEMP_MIN | Min For Temperature Test |
| PGM_FLI_MIN | Min Fuel Level For Test |
| PGM_ID_LAMN | Min Lambda For Purge |
| PGM_LOAD_MIN | Min Engine Load For Purge Test |
| PGM_MIN_SOAK | Min Soak Time 1 |
| PGM_PS0_LO | Min Tank Press For Ph0 Deadband |
| PGM_TANK_MIN | Min Tank Pressure Level For Test |
| PGM_IDVC_HLD | Min Tank Pressure Level To Increment Timer |
| PGM_IDCR_TM | Min Duration In Conditions To Beginning Ph1 Cruise Test |
| PGM_IDVC_TM | Min Duration To Hold Vacuum To Beginning Ph1 Cruise Test |
| PGM_VS_MIN | Min VSS For Test |
| PGM_RUN_CNT | Number Of Times Purge Can Run Key On Before MIL |
| PGM_STKO_LIM | Phase 4 Min Pressure Level For Stuck Open Valve |
| FNPGM_02LK_T | Purge .020" Leak Duration |
| FNPGM_IDLE_T | Purge Idle" Leak Duration |
| PGM_IDCRZ_SW | Purge Monitor Idle And Cruise Test Switch |
| PGM_IDLE_SW | Purge Monitor Idle Switch |
| FNPGM_PH2_TM | Purge Phase 2 Leak Duration |
| FN_02LK_BLDB | Tank Pressure Level Bleed Up Allowed For .020" Test |
| FN_IDLE_BLD2 | Tank Pressure Level Bleed Up Allowed Idle Test |
| FN_PGM_BLDB | Tank Pressure Level Bleed Up Allowed Purge Test |
| TPR_HI_ER | Tank Pressure Level Transducer High Deviation |
| TPR_LO_ER | Tank Pressure Level Transducer Low Deviation |
| TC_CANP | TC CANP |
| CANP_THRES | Limit For P0443 Code |
| PGM_ID_TM_MN | Duration After Beginning For Test |
| FN157B | Xnorm Canister Purge 34 |
| FN158 | Ynorm Canister Purge 34 |
| Manufacturer Name | Name |
|---|---|
| FLI_STK_TOL | FLI STK TOL |
| K_FUEL_CAL | K Fueling CAL |
| ULLAGE_FRAC | ULLAGE FRAC |
| ULLAGE_LVL | ULLAGE LVL |
| Manufacturer Name | Name |
|---|---|
| V_ADPAM_MAX | Max Air Flow For Fuel Monitor |
| V_ADPN_MAX | Max RPM For Fuel Monitor |
| V_ADPAM_MIN | Min Air Flow For Fuel Monitor |
| V_ADPN_MIN | Min RPM For Fuel Monitor |
| Manufacturer Name | Name |
|---|---|
| IAC_MON_TM | Iac Monitor Duration |
| IAC_ER_TM1 | Duration At High Deviation For Code |
| IAC_ER_TM2 | Duration At Low Deviation For Code |
| Manufacturer Name | Name |
|---|---|
| ALPHAMIS | ALPHAMIS |
| BETAMISHI | BETAMISHI |
| BETAMISLO | BETAMISLO |
| V_MIS_BGMAX | Bypass Misfire Test When BG Duration > Cal |
| BYPS_BRKPNT | BYPS BRKPNT 1 |
| FNCATMOD | Cat Temperature Limit Compensation Factor For Misfire |
| DACCELCAL_N | DACCELCAL N |
| DACCELCAL_PC | DACCELCAL PC |
| FNMISOK_97 | Inhibit Table Used By Misfire Monitor |
| V_MIS_NHYS | RPM To Turn Misfire Test On After BG |
| FNMISACT | FNMISACT |
| FNMISTR | FNMISTR |
| FNMISPCT_97 | Max Allowable Misfire Rate Before Fault |
| CF_DNDTI_MAX | Max DNDTI For Profile Compensation Adaptation |
| MIS_ECTMAX | Max ECT To Run Misfire Test |
| CF_LOAD_MAX | Max Engine Load For Profile Compensation Adaptation |
| CF_N_MAX | Max RPM For Profile Compensation Adaptation |
| V_MIS_NMAX | Max RPM To Perform Background Misfire Test |
| CF_VSBARMAX | Max VSS For Profile Compensation Adaptation |
| CF_MTR_MIN | Min Counts For Profile Compensation |
| CF_DNDTI_MIN | Min DNDTI For Profile Compensation Adaptation |
| MIS_ECTMIN | Min ECT To Run Misfire Test |
| CF_LOAD_MIN | Min Engine Load For Profile Compensation Adaptation |
| CF_N_MIN | Min RPM For Profile Compensation Adaptation |
| V_MIS_NMIN | Min RPM To Perform Background Misfire Test |
| MIS_NTQ_DEL | Min Engine Torque Drop For Misfire |
| MIS_MIN_TQ | Min Engine Torque For Misfire |
| CF_VSBARMIN | Min VSS For Profile Compensation Adaptation |
| MIS_AC_SW | MIS AC SW |
| MIS_CAT_CONF | MIS CAT CONF |
| MIS_OT_MAX | MIS OT Max |
| MIS_PTQ_DEL | MIS PTQ DEL |
| MIS_STRT_DLY | MIS STRT DLY |
| MIS_TIPIN | MIS TIPIN |
| MIS_TIPOUT | MIS TIPOUT |
| MIS1000_EWMA | MIS1000 EWMA |
| MIS200_EWMA | MIS200 EWMA |
| MISLEVEL1000 | Misfire Rate For Emissions Limit |
| MISHOT1000 | MISHOT1000 |
| MISHOT200 | MISHOT200 |
| MISID_NMAX | MISIS NMAX |
| FNMISPRMULT | Multiplier Table For Pair Limit |
| FN1615MIS | Engine Torque Table Used By Misfire Monitor |
| V_HMIS_MIN | V HMIS Min |
| FN070MIS | Xnorm Misfire Monitor 35 |
| FN034MIS | Ynorm Misfire Monitor 35 |
| Manufacturer Name | Name |
|---|---|
| US_CUR_HI | Upstream Present Monitor High Limit |
| US_CUR_LOW | Upstream Present Monitor Low Limit |
| Manufacturer Name | Name |
|---|---|
| DSRD_FREQ | Requested Frequency For EGO Test |
| EGO_ER_OV_TM | EGO ER OV TM |
| EGO_LS_ENA | EGO LS ENA |
| MAX_EGO_VOLT | EGO Voltage Level For Fault |
| LEAN_AMP_M | Lean Amplitude Limit |
| EGO_ACT_MAX | Max ACT To Run EGO Monitor |
| EGO_LAM_DLMX | Max Change In Lambda To Run Monitor |
| EGO_ECT_MAX | Max ECT To Run EGO Monitor |
| FREQERR_BAND | Max Deviation From Requested Frequency Run Test |
| LDEGO_DLTMX | Max Engine Load Change To Run Test |
| LOAD_EGO_MAX | Max Engine Load To Run Test |
| NEGO_DLTMX | Max RPM Change To Run Test |
| N_EGO_MAX | Max RPM To Run EGO Monitor |
| LAMAVE_MAX | Max Short Term Fuel Trim To Run Test |
| EGO_TPR_MAX | Max Tank Pressure Level To Run Test |
| VSEGO_DLTMX | Max VS Change To Disable Test |
| VS_EGO_MAX | Max VS To Run Test |
| EGO_ECT_MIN | Min ECT To Run EGO Monitor |
| EGO_FREQ_MIN | Min Frequency EGO Is Considered Malfunctioning |
| LOAD_EGO_MIN | Min Engine Load To Run Test |
| RBIAS_EGO_MN | Min RBIAS For Fault |
| N_EGO_MIN | Min RPM To Run EGO Monitor |
| LAMAVE_MIN | Min Short Term Fuel Trim To Run Test |
| VS_EGO_MIN | Min VS To Run Test |
| LAM_CYC_MAX | Number Of Fuel Cycles For Monitor W FAOSC |
| OV_TIME | OV Duration |
| EGO_HTR_SW | Switch To Permit EGO Monitoring |
| HTRCM_SW | Switch To Shut Off EGO Present Monitor |
| Manufacturer Name | Name |
|---|---|
| VSCNT | Failed VSS Up Counter |
| FNVMOV_LOAD | Engine Load For Inferred Movement |
| NE_VMOV_MAX | Max RPM Allowed For Inferred Movement |
| OS_MOV | Max Output VSS Allowed For Inferred Movement |
| Manufacturer Name | Name |
|---|---|
| CTLOW | ECT For Cold Beginning |
| CTHIGH | ECT For Hot Beginning |
| FN311 | Fuel Non Feedback Tp |
| FN338 | Engine Load For Non Feedback Decels |
| LLDTM | Low Engine Load Non Feedback Timer |
| VNMIN | Min RPM To Run Fuel Test |
| DCEVS | Min VSS For Non Feedback Deceleration |
| DCECTTM | Mn Tm At Closed Throttle For Non Feedback Deceleration |
| FN1311 | Non Feedback Delay Period |
| OLF_LAMBLEND | Non Feedback Delay Period Blending Ramp |
| MINDLY | Non Feedback Delay Period Timer For Wide Open Throttle |
| PURGSW | Switch To Allow Open Loop Purge |
| HEGO_WARM | Temperature For Front Hego To Go Feedback |
| HEGO_WARM_CL | Temperature For Front Hego To Go Non Feedback |
| TEMPFB | Temperature For Other Delays TEMP2 |
| V_KAMBAR_MAX | Limit To Set Adaptation Limit Code Too Lean |
| V_KAMBAR_MIN | Limit To Set Adaptation Limit Code Too Rich |
| V_LAMBAR_MAX | Limit To Set Fuel Limit Code Too Lean |
| V_LAMBAR_MIN | Limit To Set Fuel Limit Code Too Rich |
| FN_TCSTRT | Duration Delay Period For Feedback |
| OL_DELAYMAX | Duration To Delay Period Non Feedback |
| FN311X | Xnorm Open Feedback 36 |
| Manufacturer Name | Name |
|---|---|
| FN703Q | AC Head Pressure Transfer Function |
| FNCHT2R | CHT Transfer Function For Dual Resistor |
| FNCHT1R | CHT Transfer Function For Single Resistor |
| FNECT_CONV | Conversion Of CHT Into ECT |
| DWFHP | Dual Winding Fan Switch |
| FN703A | ECT/ACT Transfer Function |
| FN703F | ECT/ACT/TOT Transfer Function |
| FC_STA_DLY | Fan Delay Period After Startup |
| HSFLOD | High Speed Fan High Load Load To Turn On |
| HSFRPM | High Speed Fan High Load RPM To Turn On |
| HSFECT1_SH | High Speed Fan High Load Temperature To Turn On |
| HSFVS | High Speed Fan High Load Versus To Turn On |
| HSFECT_CL | High Speed Fan Off Ect |
| HSFECT2_SH | High Speed Fan On Ect |
| HEDFHP | High VSS Fan Switch |
| LSFVS_SL | Low Speed Fan MPH To Turn Back On |
| LSFVS_CH | Low Speed Fan MPH To Turn Off |
| LSFECT_CL | Low Speed Fan Off Ect |
| FN_ACP_LSF | Low Speed Fan On As A Function Of AC Head Pressure |
| LSFECT_SH | Low Speed Fan On Ect |
| LSF_INVRT_HP | Low Speed Fan PCM Invert Output |
| EDF_LOC | Low Speed Fan PCM Pin Location |
| ECT_CNTS_MAX | Max ECT Counts |
| Manufacturer Name | Name |
|---|---|
| ACT_ER_TM | ACT ER TM |
| ACT_LVL | ACT LVL |
| Manufacturer Name | Name |
|---|---|
| AMB_ACC_SUB | Adder To Ambient When AC Is On |
| AMB_ACT_TOL | Delta From ACT Ambient To Begin Changing |
| AMB_DELTA | Delta From ACT To Ambient |
| AMB_ECT_MIN | Min ECT Allowed For Ambient Update |
| AMB_VS_MIN | Min VSS Allowed For Ambient Update |
| TC_INFAMB | Duration Constant For Inferred Ambient |
| Manufacturer Name | Name |
|---|---|
| RF_WARMRAIL | Ambient Temperature To Switch To Higher Pressure Level |
| FUL_BOIL_DP | Fixed Pressure Drop To Run When Fuel Boiling |
| TC_FRT_SOAK | FRT Duration Constant Soak Temperature |
| FP_RTSNS_HP | Fuel Rail Temperature Level Switch |
| FNFRTMUL | Railtemp Multiplier |
| FNFRTTC | Railtemp Duration Constant |
| FUL_BOILTEMP | Railtemp When Fuel Boils |
| FRT_WGT_SOAK | Weighting Factor Of ACT&ECT During Soak |
| Manufacturer Name | Name |
|---|---|
| NLMTLO_1 | 3rd Gear High VSS Limit Exit |
| INF_NEU_ISC | Inf Neu Isc |
| NDS_MAX_LD | Max Engine Load For Neutral |
| INJ_MAX_LOAD | Max Engine Load To Turn Off Injectors |
| INJ_MAX_N | Max RPM To Turn Off Injectors |
| NDS_MIN_LD | Min Engine Load For Neutral |
| NDS_TRQ | Min Tq For Neutral |
| VSNEUT | Min VS For Neutral |
| NDS_SWPT | Neutral-drive Switch Point |
| FUL_NO_CO_SW | No Fuel Cutout Switch |
| OS_MX | Output Shaft VSS Limit |
| FNNO_LIM | Output Shaft Speed Vs Torque |
| NLMTHI_0 | Rev Limit 0 On |
| TR_N_LIM | Rev Limit Min Torque Ratio |
| NLMTNEUHI_0 | Rev Limit Neutral 0 On |
| FNRPM_LIM | Rev Limit RPM Vs Torque |
| TQ_VS_MAN | Rev Limit VSS To Exit Neutral Limiter |
| TQ_N_LIM_CL | Rev Limit Torque Off |
| TQ_N_LIM_SH | Rev Limit Torque On |
| TR_VS_MIN | Speed Limit Min Torque Ratio |
| VS_LIM_CL | Speed Limit Off |
| VS_LIM_SH | Speed Limit On |
| TQ_NO_LIM_CL | Speed Limit Output Shaft Off |
| TQ_NO_LIM_SH | Speed Limit Output Shaft On |
| FNVS_LIM | Speed Limit VS Vs Torque |
| FNTR_EOT_LIM | Torque Limit Based On EOT For ETC |
| Manufacturer Name | Name |
|---|---|
| FAO_DISABLE | FAOSC Inhibit Switch |
| RBIAS_LAM_MX | Max AF For Integral Adaptation |
| RBIAS_AVG_MX | Max Allowable Rear Bias Average |
| RBIAS_ECT_MX | Max ECT For Rear Bias Control |
| RBIAS_INT_MX | Max Integral Term For Rear Bias Control |
| RBIAS_LD_MAX | Max Engine Load For Integral Adaptation |
| PROP_LD_MAX | Max Engine Load For Proportional Bias |
| DS_CUR_HI | Max Rear O2 Heater Present |
| RBIAS_N_MAX | Max RPM For Integral Adaptation |
| PROP_N_MAX | Max RPM For Proportional Bias |
| RBIAS_MAX | Max Total Allowed Rear Bias Control |
| VEGO_FAOS_MX | Max Voltage Level For Rear Bias Control |
| RBIAS_LAM_MN | Min AF For Integral Adaptation |
| RBIAS_AVG_MN | Min Allowable Rear Bias Average |
| RBIAS_ECT_MN | Min ECT For Rear Bias Control |
| FAOP_EGO_TMP | Min Ego Temperature For Rear Bias Control |
| RBIAS_INT_MN | Min Integral Term For Rear Bias Control |
| RBIAS_LD_MIN | Min Engine Load For Integral Adaptation |
| PROP_LD_MIN | Min Engine Load For Proportional Bias |
| DS_CUR_LOW | Min Rear O2 Heater Present |
| RBIAS_N_MIN | Min RPM For Integral Adaptation |
| PROP_N_MIN | Min RPM For Proportional Bias |
| RBIAS_MIN | Min Total Allowed Rear Bias Control |
| VEGO_FAOS_MN | Min Voltage Level For Rear Bias Control |
| RBIAS_VS_MIN | Min VSS For Rear Bias Control |
| RBIAS_CL_TM | Mn Duration In Feedback For Bias Trimg |
| HEATER_HP12 | Rear O2 Heater Bank1 Downstream |
| HEATER_HP22 | Rear O2 Heater Bank2 Downstream |
| HEGO_CONFIG | Rear O2 Sensor Switch |
| DS_SWTPOINT | Rear O2 Sensor Switch Point |
| REGO_TM | REGO TM |
| DS_HTR_OFF | Temperature To Turn Off Rear O2 Heater |
| DS_HTR_ON | Temperature To Turn On Rear O2 Heater |
| TC_VEGO_FA_I | Duration Constant For Integral Control |
| FNFI__B | VEGO Setpoint For FAOSC Integral Term |
| FNFP__B | VEGO Setpoint For FAOSC Prop Term |
| FN041E__A | Xnorm Rear O2 Sensor 25 |
| FN041C__A | Ynorm Rear O2 Sensor 23 |
| Manufacturer Name | Name |
|---|---|
| RF_FFLLMUL | Adaptation Voltage Level Low Limit Multiplier |
| RF_FFULMUL | Adaptation Voltage Level High Side Limit Multiplier |
| RF_COLD_MOD | Cold Beginning Modifacation Switch |
| FNRF_LINEAR | Requested Pressure Level Drop Across Injectors |
| FPDM_OFF | Duty Cycle When Pump Is Off |
| RF_FFDDBND | Feedforward Voltage Level Deadband |
| RF_MODE | Fixed Duty Cycle Mode Switch |
| RF_DC_CAL | Fixed Duty Cycle To Run In Fixed Mode |
| FPUMP_FREQ | FPUMP FREQ |
| FRP_ERRLMT | FRP ERRLMT |
| FLI_SCP_SW | Fuel Level Input Over SCP Switch |
| FP_DGAIN_MUL | Fuel Pump Gain Cal Derivative Term |
| RF_I_GAIN | Fuel Pump Gain Cal Integral Term |
| RF_P_GAIN | Fuel Pump Gain Cal Proportional Term |
| FPC_DC_MAX | Fuel Pump Max Duty Cycle |
| FPC_DC_MIN | Fuel Pump Min Duty Cycle |
| FNRF_SSFF | Fuel Pump Voltage Level Table |
| FNRGP | Fuel Rail Pressure |
| FRP_ERRTOL | Fuelpump Tst Quantity Of Fuel Pressure Level Drop Deviation |
| FRP_MID | Fuelpump Tst Deviation Buffer |
| FRP_RATE | Fuelpump Tst Max Rate Of Fuel Pressure Level Change |
| FRP_MIDTOL | Fuelpump Tst Pressure Level Below Allowed For Test |
| FNRF_COLD | Injector Pressure Level Drop Change When Cold |
| FNRF_BOIL | Injector Pressure Level Drop Change With ACT |
| RF_FRDPS_MAX | Max Counts For IPS Sensor To Be Good |
| MAX_DPREF | Max DPREF |
| RF_FRDPS_MIN | Min Counts For IPS Sensor To Be Good |
| FP_FRTS_TM | P0183 Fault Timer Set High |
| FP_FRDPS_TM | P0190 P0193 Fault Timer Set High |
| FLI_ER_TM2 | P0463 Fault Timer Set High |
| FNRF_DP_ADC | Pressure Level Sensor Transfer Relationship |
| RF_FF_ADAPT | Switch To Turn On/Off Adaptation Fuel Pump Volt |
| RF_UPRATE | Duration Between Adaptation Updates |
| RF_DP_ERR_TC | Duration Constant For Delta P Across Injectors |
| FNFP_IR_DROP | Voltage Drop To FPDM |
| FNRFNRM_FLOW | Xnorm Returnless Fueling Pump 37 |
| FNRFNRM_RAP | Ynorm Returnless Fuel Pump 23 |
| Manufacturer Name | Name |
|---|---|
| LUHTOT_SH | Hot Lock Enter Temperature |
| LUHTOT_CL | Hot Lock Exit Temperature |
| CS_MAX_TIME | Max Duration To Spend In Cold Shift Mode |
| NELUMN | Min RPM To Lock |
| SRLKOT | Min VSS Ratio To Lock Hot Mode |
| VSLUMN | Min VSS To Lock |
| FN690 | Tot To Exit Cold Shift |
| Manufacturer Name | Name |
|---|---|
| NE12S4L | Trans Wot Shift RPM 12 4x4 Low |
| NE23S4L | Trans Wot Shift RPM 23 4x4 Low |
| NE34S4L | Trans Wot Shift RPM 34 4x4 Low |
| Manufacturer Name | Name |
|---|---|
| VS21PI | 2-1 Pullin Max Speed |
| VS32P2 | 3-2 Pullin Max Speed |
| NEHSM1 | RPM To Shift Into 2 In Manual 1 |
| PDLTIM | Shifter Residence Timer |
| VS43PI | Speed To Override O/d Cancel Input |
| TM_HS_M12 | Duration To Command 3rd On Manual 1-2 |
| TM_M12 | Duration To Delay Manual 1 Override |
| Manufacturer Name | Name |
|---|---|
| PWF_DEC_E | Performance Decrement Factor |
| FNPWFE | Performance Weighting Factor |
| TMHOLDPWF | Tm To Hold Weight Factor After Upshift |
| FNPWFX | Xnorm Performance Shift Schedule 27 |
| FNPWFY | Ynorm Performance Shift Schedule 25 |
| Manufacturer Name | Name |
|---|---|
| TCVSRSS | Filter For Vehicle Acceleration Rate Predictive |
| TCVS | Filter For Vehicle Speed |
| VSRATE_MAX | Max Vehicle Acceleration Rate |
| TPNEPUMIN | Min Pedal For Predictive Shift |
| NEPUMIN | Min RPM For Predictive Shift |
| NE12S | Trans Wot Shift RPM 12 |
| NE23S | Trans Wot Shift RPM 23 |
| NE34S | Trans Wot Shift RPM 34 |
| Manufacturer Name | Name |
|---|---|
| FN12PPH | 1-2 Shift PPH Function |
| FN23PPH | 2-3 Shift PPH Function |
| FN34PPH | 3-4 Shift PPH Function |
| Manufacturer Name | Name |
|---|---|
| FN12S | Trans Shift Schedule 12 |
| FN21S | Trans Shift Schedule 21 |
| FN23S | Trans Shift Schedule 23 |
| FN32S | Trans Shift Schedule 32 |
| FN34S | Trans Shift Schedule 34 |
| FN43S | Trans Shift Schedule 43 |
| Manufacturer Name | Name |
|---|---|
| VSCTDY | Speed Above To Lock Converter At CT |
| U12DLY | Duration To Delay Period Conv Lk After 12 |
| D21DLY | Duration To Delay Period Conv Lk After 21 |
| U23DLY | Duration To Delay Period Conv Lk After 23 |
| D32DLY | Duration To Delay Period Conv Lk After 32 |
| TMD2SLP | Duration To Delay Conv Lk After 32b |
| U34DLY | Duration To Delay Period Conv Lk After 34 |
| D43DLY | Duration To Delay Period Conv Lk After 43 |
| TMD3SLP | Duration To Delay Conv Lk After 43b |
| TMCTDY | Time Required To Delay Conv Lk After Tip In From CT |
| UWOTDLY | Duration To Delay Period Conv Lk At Wide Open Throttle |
| TPUNWOT | TP Above To Delay Period Conv Lk At Wide Open Throttle After Shift |
| FN2LS | Trans Converter Lock 2nd |
| FN3LS | Trans Converter Lock 3rd |
| FN4LS | Trans Converter Lock 4th |
| FN2US | Trans Converter Unlock 2nd |
| FN3US | Trans Converter Unlock 3rd |
| FN4US | Trans Converter Unlock 4th |
| Manufacturer Name | Name |
|---|---|
| FN615TQ | Trans Shift Schedule Torque Compensation Factor |
| Manufacturer Name | Name |
|---|---|
| FN1329A | Firing Order |
| SPK_ADD | Global Ignition Timing Adder |
| SPK_MUL | Global Ignition Timing Multiplier |
| TQ_TIP_NMAX | Max RPM For Tip In Tq Control |
| FN741 | Max Ignition Timing When At Low Engine Load |
| SPUCLP | Max Ignition Timing Limit |
| TQ_TIP_NMIN | Min RPM For Tip In Tq Control |
| TQ_TIP_VS | Min VSS For Tip In Tq Control |
| SPLCLP | Min Ignition Timing Limit |
| SPK_OCT_NUM1 | RON Octane For Borderline Ignition Timing Table |
| SPK_OCT_NUM2 | RON Octane For Borderline Ignition Timing Table 2 |
| FN721 | Spark Adder For EGR |
| FN2600 | Ignition Timing For Deceleration |
| SPK_LUGSW | Ignition Timing Lug Switch |
| FN017E | Xnorm Ignition Timing 39 |
| Manufacturer Name | Name |
|---|---|
| FN2200 | Borderline Knock Table |
| FN2225 | Octane Plug Ignition Timing Compensation Factor |
| FN2250 | Ignition Timing Adder After Engine Load Increase |
| FN2240B | Ignition Timing Adder For A/F When Open Loop |
| FN2230 | Ignition Timing Retard Act Multiplier |
| FN2220 | Ignition Timing Retard Ect Multiplier |
| FN725A | Ignition Timing Retard For Act |
| FN724A | Spark Retard For Ect |
| FN016 | Xnorm Borderline Knock 29 |
| FN017 | Xnorm Ignition Timing 38 |
| FN070X | Xnorm Borderline Knock 40 |
| FN012 | Ynorm Borderline Knock 26 |
| FN013 | Ynorm Ignition Timing 38 |
| FN015W | Ynorm Borderline Knock 28 |
| Manufacturer Name | Name |
|---|---|
| FN2001A | Adder Max Allowed Ignition Timing Cold For RPM/Engine Load |
| FN2002 | Adder Max Allowed Spark Cold For TP/cattemp |
| CSSR_MAXISC | Max ISC Duty Allowed For Cold Beginning Ignition Timing |
| FN2000D | Maximum Allowed Ignition Timing Table Cold Starts |
| CSSR_MN_MVAC | Min Man Vac Allowed For Cold Beginning Ignition Timing |
| SPK_CSSR_EGR | SPK CSSR EGR |
| SPK_LOLD_STP | SPK LOLD STP |
| STAB_LOLD_AM | STAB LOLD AM |
| FN020D | Xnorm Cold Beginning 41 |
| FN028 | Xnorm Cold Start 30 |
| FN018G | Ynorm Cold Start 29 |
| FN029 | Ynorm Cold Start 27 |
| Manufacturer Name | Name |
|---|---|
| FN760 | Quantity Of Engine Torque Reserve For Idle |
| FNIFBS_D | Requested Idle Ignition Timing Drive |
| FNIFBS_N | Requested Idle Ignition Timing Neutral |
| FBS_ENTRY_TC | Feedback Ignition Timing Entry Duration Constant |
| FNSPKFBSGAIN | Idle Ignition Timing Prop Gain Cal Ignition Timing |
| SPK_FBS_MIN | Lowest Ignition Timing Value Used For Idle Control |
| SPK_FBS_DLT | Min Allowed Retard From MBT For Idle |
| FN797 | Ignition Timing Retard To Engine Torque Ratio For Idle |
| FN767 | Engine Torque Ratio To Ignition Timing Retard For Idle |
| Manufacturer Name | Name |
|---|---|
| COIL_NMAX | Max RPM For Coil Test |
| REPET_SPK_HI | Repetitive Ignition Timing Inhibit RPM |
| REPET_SPK_LO | Repetitive Ignition Timing Re Permit RPM |
| Manufacturer Name | Name |
|---|---|
| SPKAD_CYL1 | Global Ignition Timing Adder For Cylinder 1 |
| SPKAD_CYL10 | Global Ignition Timing Adder For Cylinder 10 |
| SPKAD_CYL2 | Global Ignition Timing Adder For Cylinder 2 |
| SPKAD_CYL3 | Global Ignition Timing Adder For Cylinder 3 |
| SPKAD_CYL4 | Global Ignition Timing Adder For Cylinder 4 |
| SPKAD_CYL5 | Global Ignition Timing Adder For Cylinder 5 |
| SPKAD_CYL6 | Global Ignition Timing Adder For Cylinder 6 |
| SPKAD_CYL7 | Global Ignition Timing Adder For Cylinder 7 |
| SPKAD_CYL8 | Global Ignition Timing Adder For Cylinder 8 |
| SPKAD_CYL9 | Global Ignition Timing Adder For Cylinder 9 |
| Manufacturer Name | Name |
|---|---|
| FN2300A | MBT Ignition Timing Table |
| FN2335 | Ignition Timing Adder For MBT Using EGR |
| FN2150CMB | Ignition Timing Adj For Combustion Noise |
| FN2150EMI | Spark Adj For Emissions |
| FN730 | Ignition Timing Modifier For MBT Based On A/F Ratio |
| FN2320 | Ignition Timing Retard Ect Multiplier To MBT |
| FN014 | Xnorm MBT Ignition Timing 44 |
| FN013PCT | Ynorm MBT Spark 28 |
| Manufacturer Name | Name |
|---|---|
| FN702 | Ignition Timing Compensation Factor For ECT |
| Manufacturer Name | Name |
|---|---|
| FN704A | Max Spk Retard For Tip In Based On RPM |
| SPK_ARCH_MIN | Limit To Identify Ending Of Tip In |
| SPK_D_AIRCHG | Limit To Identify Tip In |
| FN732 | Tip In Borderline Modifier Slope ECT |
| FN1142 | Tip In Spark Retard Table For Change In AM |
| FN024F | Ynorm Tip In Spark Retard 29 |
| Manufacturer Name | Name |
|---|---|
| FN040A | Estimated Aircharge Func RPM |
| FN004 | Exhaust Backpressure Correction Func BP |
| FN052M | MAP At Zero Aircharge |
| FN035A | Peak Load At Sealevel |
| FN052N_C | Slope Of MAP Vs Aircharge Closed IMRC |
| FN052N_O | Slope Of MAP Vs Aircharge Open IMRC |
| FN059 | Temp Correction For Voleff |
| FN074B | Upstream Pressure Func Air Mass |
| FN1052 | Voleff Compensation For ECT&ACT |
| FN022V | Xnorm VSS Density 48 |
| FN052BP | Y Intercept Compensation Of Mapping Vs Aircharge |
| FN022V | Ynorm VSS Density 47 |
| Manufacturer Name | Name |
|---|---|
| HP_4X4L | 4x4 Low Switch |
| AC_RLY_IS_NC | AC Relay Normally Closed |
| HPACL | Adjustable Shock Control Switch |
| ACL_PLSE_HP | Adjustable Shock Pulse HP |
| ACPSEN_HP | Air Cond Pressure Level Sensor Switch |
| ACCS_HP | Air Cond Switch |
| BPSSW | BP Sensor Switch |
| BIHP_SCP | Brake Input Scp Switch |
| BIHP | Brake Input Switch |
| PCOMP_SW | Canister Purge Compensation Switch |
| PCOMP_ENA_SW | Canister Purge Permit Switch |
| PRG_FLOW_SW | Canister Purge Flow Test Switch |
| PGM_HW_SW | Canister Purge Monitor Switch |
| PGM_SELECT | Canister Purge Selection Switch |
| CCL_CHK | Check Fueling Cap Bulb Check |
| CHT_SNS_HP | Cht Sensor Switch |
| ECT_SNS_HP | Ect Sensor Switch |
| PFEHP | EGR Type Switch |
| EDFHP | Electrodrive Fan Switch |
| EOT_HP | EOT Switch |
| ETC_HP | Etc Switch |
| RFS_TYPESEL | Fuel Pump System Type |
| FP_TYPE_SEL | Fuel Pump Type |
| IMRCSENSHP | Imrc Sensor Type |
| IMRCHP | Imrc Switch |
| DEGPIP | Number Of Crank Degrees Per PIP |
| NUMCYL_0 | Number Of Cylinders |
| ENGCYL | Number Of Cylinders /2 |
| OS_PULS_REV | Number Of Holes For OSS Sensor |
| KNK_SENSORS | Number Of Knock Sensors |
| OSS_HP | Oss Switch |
| PATS_DISABLE | PATS Inhibit Switch |
| PSPSHP | Powersteering Pressure Level Switch |
| PSPTHP | Powersteering Pressure Level Transducer Sw |
| PTO_HP | Pto Switch |
| PUL_PER_REV | PUL PER REV |
| TCIL_FL_SW | Switch To Flash TCIL For Fault |
| NEUTRAL_SW | Switch To Force To Neutral |
| TID_CPP_SW | Switch To Shut Off Continous CPP Test |
| THRMHP | Thermactor Switch |
| TQ_OSC_SW | Tip In Oscillation Switch |
| TQ_MODULE_SW | Engine Torque Module Switch |
| AUTO_TRNS_SW | Trans Auto Switch |
| TRLOAD | Trans Engine Load Switch |
| TSTRAT | Trans Type |
| TCSS_HP | Transfer Case Switch |
| HP_CIDSEL | Type Of Cam Sensors |
| TID_CPP_MODE | Value Used For INDS When Clutch Is Pushed |
| VCAMHP | Variable Cam Switch |
| PCM_VSO_SW | PCM VSS Source Enable |
| VS_HP | Vehicle Speed Sensor Switch |
| VSHP_SCP | VSS Sensor Switch Over SCP |
| VSTYPE | Vehicle Speed Sensor Type |
| Manufacturer Name | Name |
|---|---|
| FN632 | A/F Ratio As Function Of Engine Torque Ratio |
| INERTIA_ENG | Engine Inertia |
| FN612 | Multiplier To Engine Torque Using % Ethanol |
| FN766 | Ignition Timing Retard To Engine Torque Ratio |
| FN623 | Engine Torque Compensation Factor As Function Of A/F Ratio |
| FN799 | Engine Torque Ratio To Ignition Timing Retard |
| FNINDICATED | Torque Table |
| FNFRIC_MOTOR | Torque Table Friction |
| FNTQ_NORM_N | Xnorm Engine Torque Calculation 50 |
| FNTQ_NORM_LD | Ynorm Engine Torque Calculation 50 |
| Manufacturer Name | Name |
|---|---|
| SLIP_DES_MIN | Amnt Of Desired Converter Slip During Shift |
| ACSLIP | Desired Converter Slip When AC Applies |
| K_CLUTCH | Gain Cal Of Converter Clutch Plate Psi/Ft Lb |
| MAXSLIP1 | Max Quantity Of Requested Slip |
| AC_CTL_OFF | Max Exit Duration For Converter Slip W/AC |
| AC_SLP_WDOG | Max Duration For Converter Slip W/AC |
| TMCTDY | Time Required To Delay Conv Lk After Tip In From CT |
| VSCTDY | Speed Above To Lock Converter At CT |
| SRLUMN | Minimum Spd Ratio To Lock |
| FNUPSSFT23 | Multiplier Of Cap During 23 Shift |
| FNUPSSFT34 | Multiplier Of Cap During 34 Shift |
| OPNRMPMULTL | Multiplier On Cap For Unlocks |
| OPNRMPMULTU | Multiplier On Cap Locked To Slip W Shift |
| OPNRMPMULT | Multiplier On Cap Locked To Slipping |
| OPNRMPOFFL | Offset On Cap For Unlocks |
| OPNRMPOFFU | Offset On Cap Locked To Slip W Shift |
| OPNRMPOFF | Offset On Cap Locked To Slipping |
| MXRMPOPENTM | Ramp Open Max Duration |
| SLPRMPOPN | Ramp Open Slip |
| FN_SRLK | VSS Ratio To Lock Converter |
| FN2SSLP | Steady State Torque Conv Slip 2nd Gear |
| FN3SSLP | Steady State Torque Conv Slip 3rd Gear |
| FN4SSLP | Steady State Torque Conv Slip 4th Gear |
| TPUNBRK | TPS To Not Unlock W Brake |
| TPUNCT | TPS To Open Conv At Closed Thr |
| TRUHAC | Throttle Rate To Unlock HiTP Tip-in |
| TRUHDC | Throttle Rate To Unlock HiTP Tip-out |
| TRULAC | Throttle Rate To Unlock LowTP Tip-in |
| TRULDC | Throttle Rate To Unlock LowTP Tip-out |
| AC_CTL_TM | Duration Allowed For Converter Slip W/AC |
| CTDLY | Duration To Delay Period Lockup During Tip In |
| OTCTDLY | Duration To Delay Period Lockup During Tip In Over Temperature |
| UNLKDLYTM | Time To Remain Locked Closed Throttle |
| UNLKDLYTM4 | Duration To Remain Locked Closed Throttle 4th |
| BRKRLCKTM | Duration To Remain Unlocked After Brake Input |
| TCAP_HLK | Torque Capacity Multiplier For HL |
| FN067 | Xnorm Misc 49 |
| FN114A | Ynorm Misc 70 |
| FN114B | Ynorm Misc 71 |
| FN114C | Ynorm Misc 72 |
| Manufacturer Name | Name |
|---|---|
| TMCLUP2 | Feedback Upshift To 2nd |
| TMCLUP3 | Feedback Upshift To 3rd |
| TMCLUP4 | Feedback Upshift To 4th |
| DSRU2 | Delta Ratio For 12 Shift |
| DSRUE2 | Delta Ratio For 12 Shift End |
| DSRU3 | Delta Ratio For 23 Shift |
| DSRUE3 | Delta Ratio For 23 Shift End |
| DSRU4 | Delta Ratio For 34 Shift |
| DSRUE4 | Delta Ratio For 34 Shift End |
| TMOLUP2 | Open Loop Upshift To 2nd |
| TMOLUP3 | Open Loop Upshift To 3rd |
| TMOLUP4 | Open Loop Upshift To 4th |
| Manufacturer Name | Name |
|---|---|
| STROKE_DRP | Amount Of RPM Drop To Signal Conv Is Locking |
| TCUPS | Filter For Desired Slip During Shifts |
| TCLCK | Filter For Desired Slip Higher TP |
| TCLCKL | Filter For Desired Slip Lower TP |
| STROKE_TM | Duration To Hold Conv Cl When Applying |
| TCRMP_HK | Torque Converter Lockup Rate After Tip In |
| TCRMP_HK_SFT | Torque Converter Lockup Rate After Upshift |
| TCRMP_HK_TP | Torque Converter Lockup Rate W/high Tp |
| Manufacturer Name | Name |
|---|---|
| FNANTI_STALL | Min Engine Torque Allowed |
| FNTR_SAI_SET | Engine Torque Reduction By Ignition Timing Only |
| FNTR_SPK_LVL | Engine Torque Reduction Ignition Timing Authority |
| Manufacturer Name | Name |
|---|---|
| DLY_UNCLK_TQ | Delay Duration To Unlock For TQ |
| MX_ALLOW_SLP | Max Slip Across Conv To Be Excessive |
| FNTQ_MX1 | Torque Limit Table 1st Gear |
| FNTQ_MX2 | Torque Limit Table 2nd Gear Open Conv |
| FNTQ_MX3CC | Torque Limit Table 3rd Gear Locked Conv |
| TQ_MAX_HRD3 | Torque Limit Table 3rd Gear Locked Conv 1 |
| FNTQ_MX3 | Torque Limit Table 3rd Gear Open Conv |
| FNTQ_MX4CC | Torque Limit Table 4th Gear Locked Conv |
| TQ_MAX_HRD4 | Torque Limit Table 4th Gear Locked Conv 1 |
| FNTQ_MX4 | Torque Limit Table 4th Gear Open Conv |
| FNTQ_MX5CC | Torque Limit Table 5th Gear Locked Conv |
| FNTQ_MX5 | Torque Limit Table 5th Gear Open Conv |
| FNTQ_MX0 | Torque Limit Table Not Forward |
| FNTQ_MAX | Torque Truncation Table |
| FNMX_LK_TQ2 | Tq Limit Table 2nd Gear Locked Conv Hot |
| FNMX_LK_TQ3 | Tq Limit Table 3rd Gear Locked Conv Hot |
| FNMX_LK_TQ4 | Tq Limit Table 4th Gear Locked Conv Hot |
| FNMX_LK_TOT | Xnorm Auto Trans 37 |
| FNMX_LK_RPM | Ynorm Auto Trans 35 |
| Manufacturer Name | Name |
|---|---|
| FNUP1DLY | Clutch Fill Duration 12 Shift |
| FNUP2DLY | Clutch Fill Duration 23 Shift |
| FNUP3DLY | Clutch Fill Duration 34 Shift |
| NE34COMP | Compensation For TQ Loss |
| TSTBCSDC | Duty Cycle To Lock In |
| NEDROP | RPM Drop For Shift |
| GRMSFT | Gear To Lock In To |
| TCC_LK_LVL | Level For Setting TCC Fault |
| MAXNEPU | Max Engine RPM Accel Rate For Anticipated Shifting |
| TP_SH_VAL2 | Min Tp For 1-2 Shift Validation |
| TP_SH_VAL3 | Min Tp For 2-3 Shift Validation |
| TP_SH_VAL4 | Min Tp For 3-4 Shift Validation |
| VS_SH_VAL2 | Min Vs For 1-2 Shift Validation |
| VS_SH_VAL3 | Min Vs For 2-3 Shift Validation |
| VS_SH_VAL4 | Min Vs For 3-4 Shift Validation |
| FN689U | RPM Based Shifts For Failed VSS |
| FN689V | RPM For Failed Speed Sensor |
| FNSSCTL2 | Shift Solenoid Truth Table |
| SFT_ERR_UP | Shift Validation Up Counter |
| SWBCTST | Switch To Lock Converter |
| SW_MSF | Switch To Lock In Gear |
| NEPU_SW | Switch To Use RPM Anticipated Shifts |
| FNTOTDLY | TOT Delay Period Multiplier |
| TOT_OTEMP_S | Trans Temperature For Entering Over Temperature |
| VSU4HOT | Wide Open Throttle RPM For Overtemp |
| Manufacturer Name | Name |
|---|---|
| GR_SEQ_421 | First Step 0f 42 Kickdown |
| GR_SEQ_131 | First Step Of A 1-3 Shift |
| GR_SEQ_141 | First Step Of A 1-4 Shift |
| TCUPON12 | Duration For 12 Upshift To Complete |
| TCUPON23 | Duration For 23 Upshift To Complete |
| TCUPON34 | Duration For 34 Upshift To Complete |
| TCDN1ON | Duration For Downshift Into 1st To Complete |
| TCD43ON | Duration For Downshift Into 3rd To Complete |
| TCDNON | Duration For Downshift To Complete |
| TMSQ21P1 | Duration To Sequence 21 In Manual 1 |
| TMSQ32P2 | Duration To Sequence 32 In Manual 2 |
| FNTMSEQ32P4 | Duration To Sequence 42 Kickdown |
| TMSQ23P4 | Duration To Stay In 2nd Before 3rd |
| TMSQ34P4 | Duration To Stay In 3rd Before 4th |
| TCDNMF | Duration To Use Pressure For Manual Shift |
| TMVEDN | Duration To Verify Downshift |
| TMVEUP | Duration To Verify Upshift |
| FNXVSBART_RT | Xnorm Gear Timing 38 |
| FNXTMINGR4 | Ynorm Gear Timing 36 |
| Manufacturer Name | Name |
|---|---|
| TVPMIN_2 | Minimum TV Pwr/off Into 2nd |
| TVPMIN_3 | Minimum TV Pwr/off Into 3rd |
| TVPMIN_4 | Minimum TV Pwr/off Into 4th |
| TVPMINPT_2 | Minimum TV Pwr/on Into 2nd |
| TVPMINPT_3 | Minimum TV Pwr/on Into 3rd |
| TVPMINPT_4 | Minimum TV Pwr/on Into 4th |
| SCINT1 | Pressure Offset 1st Gear |
| SCINT2 | Pressure Offset 2nd Gear |
| SCINT3 | Pressure Offset 3rd Gear |
| SCINT4 | Pressure Offset 4th Gear |
| Manufacturer Name | Name |
|---|---|
| FN12TPOT | 1-2 Shift Pressure Multiplier Cold |
| FN21T | 2-1 Shift Pressure Multiplier Cold |
| SCSLP1SD | Downshift Slope Into 1 |
| TVPMIN_1 | Minimum TV Pwr/off Into 1st |
| TVPMINPT_1 | Minimum TV Pwr/on Into 1st |
| FN12DYTX_VS | Trans Tv Pressure 12 |
| FN21DYTX_VS | Trans Tv Pressure 21 |
| SCSLP2SU | Upshift Slope Into 2 |
| FNX12T | Xnorm 1-2 2-1 Shift 39 |
| FN101 | Xnorm 1-2 2-1 Shift 40 |
| FNX21T | Xnorm 1-2 2-1 Shift 41 |
| FNX12V | Ynorm 1-2 2-1 Shift 37 |
| FN067C | Ynorm 1-2 2-1 Shift 38 |
| FNX21V | Ynorm 1-2 2-1 Shift 39 |
| Manufacturer Name | Name |
|---|---|
| FN42DYTX_VS | Trans Tv Pressure 42 |
| FNX42T | Xnorm 1-4 2-4 4-2 4-1 Shift 42 |
| FNX42V | Ynorm 1-4 2-4 4-2 4-1 Shift 40 |
| Manufacturer Name | Name |
|---|---|
| FN23TPOT | 2-3 Shift Pressure Multiplier Cold |
| FN32T | 3-2 Shift Pressure Multiplier Cold |
| SCSLP2SD | Downshift Slope Into 2 |
| FN23DYTX_VS | Trans Tv Pressure 23 |
| FN32DYTX_VS | Trans Tv Pressure 32 |
| SCSLP3SU | Upshift Slope Into 3 |
| FNX23T | Xnorm 2-3 3-2 Shift 43 |
| FNX32T | Xnorm 2-3 3-2 Shift 44 |
| FNX23V | Ynorm 2-3 3-2 Shift 41 |
| FNX32V | Ynorm 2-3 3-2 Shift 42 |
| Manufacturer Name | Name |
|---|---|
| FN34TPOT | 3-4 Shift Pressure Multiplier Cold |
| FN43T | 4-3 Shift Pressure Multiplier Cold |
| SCSLP3SD | Downshift Slope Into 3 |
| FN34DYTX_VS | Trans Tv Pressure 34 |
| FN43DYTX_VS | Trans Tv Pressure 43 |
| SCSLP4SU | Upshift Slope Into 4 |
| FNX34T | Xnorm 3-4 4-3 Shift 45 |
| FNX43T | Xnorm 3-4 4-3 Shift 46 |
| FNX34V | Ynorm 3-4 4-3 Shift 43 |
| FNX43V | Ynorm 3-4 4-3 Shift 44 |
| Manufacturer Name | Name |
|---|---|
| FNM12A | Added Pressure For Manual 12 Shift |
| TVBLPM21 | Added Pressure For Manual 21 Shift |
| FNM23A | Added Pressure For Manual 23 Shift |
| TVBLP32 | Added Pressure For Manual 32 Shift |
| TVBLP43 | Added Pressure For OD Cancel |
| FNBLPM21 | Duration For Added Pressure On Manual 21 |
| FNBLP32V | Duration For Added Pressure On Manual 32 |
| FNBLPM32 | Duration For Added Pressure On Manual 32 1 |
| FNBLPM43 | Duration For Added Pressure On OD Cancel |
| Manufacturer Name | Name |
|---|---|
| TVPMINST_1 | Minimum TV Nonshifting 1st |
| TVPMINST_2 | Minimum TV Nonshifting 2nd |
| TVPMINST_3 | Minimum TV Nonshifting 3rd |
| TVPMINST_4 | Minimum TV Nonshifting 4th |
| SCSLP1 | Nonshift Slope 1 |
| SCSLP2 | Nonshift Slope 2 |
| SCSLP3 | Nonshift Slope 3 |
| SCSLP4 | Nonshift Slope 4 |
| Manufacturer Name | Name |
|---|---|
| FN616F | Engagement Curve W/TP Forward |
| FN616R | Engagement Curve W/TP Reverse |
| FNXTOD | Engagement Table Into Forward Gear |
| FNXTOR | Engagement Table Into Reverse Gear |
| FNPNN | Neutral Pressure |
| FNENGRMP | Pressure Ramp For Engagement |
| FN616_SW | Switch To Use Forward Engagement Curve Always |
| FNTMDRVREV | Duration For Drive To Reverse Engagement |
| FNTMNEUDRV | Duration For Neutral To Drive Engagement |
| FNTMNEUREV | Duration For Neutral To Reverse Engagement |
| FNTMREVDRV | Duration For Reverse To Drive Engagement |
| TMENGACT | Duration To Complete Engagement |
| FNDRTM | Duration To Delay D-R Pressure Ramp |
| FNNDTM | Duration To Delay N-D Pressure Ramp |
| FNNRTM | Duration To Delay N-R Pressure Ramp |
| FNRDTM | Duration To Delay R-D Pressure Ramp |
| FNXTODX | Xnorm Engagements 47 |
| FNXTORX | Xnorm Engagements 48 |
| FNXTODY | Ynorm Engagements 45 |
| FNXTORY | Ynorm Engagements 46 |
| Manufacturer Name | Name |
|---|---|
| PCTU2A | % Reduction For Step 1 Of 12 Shift |
| PCTU3A | % Reduction For Step 1 Of 23 Shift |
| PCTU4A | % Reduction For Step 1 Of 34 Shift |
| PCTU2B | % Reduction For Step 2 Of 12 Shift |
| PCTU3B | % Reduction For Step 2 Of 23 Shift |
| PCTU4B | % Reduction For Step 2 Of 34 Shift |
| PCTU2C | % Reduction For Step 3 Of 12 Shift |
| PCTU3C | % Reduction For Step 3 Of 23 Shift |
| PCTU4C | % Reduction For Step 3 Of 34 Shift |
| PCTU2D | % Reduction For Step 4 Of 12 Shift |
| PCTU3D | % Reduction For Step 4 Of 23 Shift |
| PCTU4D | % Reduction For Step 4 Of 34 Shift |
| PCTU2E | % Reduction For Step 5 Of 12 Shift |
| PCTU3E | % Reduction For Step 5 Of 23 Shift |
| PCTU4E | % Reduction For Step 5 Of 34 Shift |
| FNTQDM41V | Hold Duration For Tq Mod On 41 Downshift |
| FNTQDM42V | Hold Duration For Tq Mod On 42 Downshift |
| FNTQDM1V | Hold Duration For Tq Mod On Downshift To 1st |
| FNTQDM2V | Hold Duration For Tq Mod On Downshift To 2nd |
| FNTQDM3V | Hold Duration For Tq Mod On Downshift To 3rd |
| FNTQDNWD | Max Duration For Tq Mod On Downshift |
| FNTQUPWD | Max Duration For Tq Mod On Upshift |
| ECT_TQM | Min ECT For Engine Torque Reduction On Shifts |
| TP_MIN_TQ_DN | Min Tp For Torque Reduction On Downshifts |
| TP_MIN_TQM | Min Tp For Torque Reduction On Shifts |
| TP_MIN_TQ_UP | Min Tp For Torque Reduction On Upshifts |
| FNTQDF41V | Ramp Duration For Finish Of Tq Mod On 41 Downshift |
| FNTQDF42V | Ramp Duration For Finish Of Tq Mod On 42 Downshift |
| FNTQDF1V | Ramp Duration For Finish Of Tq Mod On Downshift To 1st |
| FNTQDF2V | Ramp Duration For Finish Of Tq Mod On Downshift To 2nd |
| FNTQDF3V | Ramp Duration For Finish Of Tq Mod On Downshift To 3rd |
| FNTQDS41V | Ramp Duration For Strt Of Tq Mod On 41 Downshift |
| FNTQDS42V | Ramp Duration For Strt Of Tq Mod On 42 Downshift |
| FNTQDS1V | Ramp Duration For Strt Of Tq Mod On Downshift To 1st |
| FNTQDS2V | Ramp Duration For Strt Of Tq Mod On Downshift To 2nd |
| FNTQDS3V | Ramp Duration For Strt Of Tq Mod On Downshift To 3rd |
| FNTMTQDS41 | Duration Dly For Strt Of Tq Mod On 41 Downshift |
| FNTMTQDS42 | Duration Dly For Strt Of Tq Mod On 42 Downshift |
| FNTMTQDS1 | Duration Dly For Strt Of Tq Mod On Downshift To 1st |
| FNTMTQDS2 | Duration Dly For Strt Of Tq Mod On Downshift To 2nd |
| FNTMTQDS3 | Duration Dly For Strt Of Tq Mod On Downshift To 3rd |
| SW_TQM | Torque Modulation Switch |
| FNPCTU2 | Torque Reduction 12 Shift |
| FNPCTD1 | Torque Reduction 21 Shift |
| FNPCTU3 | Torque Reduction 23 Shift |
| FNPCTD2 | Torque Reduction 32 Shift |
| FNPCTU4 | Torque Reduction 34 Shift |
| FNPCTD3 | Torque Reduction 43 Shift |
| FNDLTUF2 | Tq Mod End For 12 Shift |
| FNDLTUF3 | Tq Mod End For 23 Shift |
| FNDLTUF4 | Tq Mod End For 34 Shift |
| FNDLTUS2 | Tq Mod Start For 12 Shift |
| FNDLTUS3 | Tq Mod Start For 23 Shift |
| FNDLTUS4 | Tq Mod Start For 34 Shift |
| FNTQIAN | Xnorm Trans Torque Reduction 50 |
| FNTQTPN | Ynorm Trans Torque Reduction 50 |
| Manufacturer Name | Name |
|---|---|
| FILFRC | Cylinder Air Charge Ratio Below To Use Deceleration Multiplier |
| ACDC_TI_LIM | Tip In Lead Compensation Limit |
| ACDC_TO_LIM | Tip Out Lead Compensation Limit |
| FN285 | Transient Fueling MULT For IMRC When Closing |
| FN286 | Transient Fueling MULT For IMRC When Opening |
| FNIMRC_MLT | Transient Fuel Multiplier When IMRC Open/closed |
| FNTFC_X_VT | Transient Fuel Temperature Based Fuel That Is Trapped |
| FNTFC_T_VT | Transient Fuel Temperature Based Rate Fuel Leaves Puddle |
| FNTFC_X | Transient Fuel That Is Trapped In Puddle |
| FN022VT | Xnorm Transient Fueling 63 |
| FN022F | Xnorm Transient Fueling 61 |
| FN018T | Ynorm Transient Fueling 75 |
| FN039T | Ynorm Transient Fueling 73 |
| Manufacturer Name | Name |
|---|---|
| CIDTSTLVL | Test Level For Code P0340 |
| Manufacturer Name | Name |
|---|---|
| RTAXLE_MXCLP | Max Axle Ratio For VID Block |
| RT_AXLE_MX | Max Axle Ratio That Is Certified |
| VID_NOV_MX | Max N/V For VID Block |
| TIRE_REV_MX | Max Tire Revs That Is Certified |
| RTAXLE_MNCLP | Min Axle Ratio For VID Block |
| RT_AXLE_MN | Min Axle Ratio That Is Certified |
| VID_NOV_MN | Min N/V For VID Block |
| TIRE_REV_MN | Min Tire Revs That Is Certified |
| Manufacturer Name | Name |
|---|---|
| FN822B | Air Flow Adder Based On Duration On |
| HSFAN_DELAY | Delay Period When Turning On The High VSS Fan |
The public preview intentionally does not display raw addresses, offsets, data sizes, scaling values or other underlying definition information. The complete mapping is included with the purchased definition.
ADDITIONAL EEC-V INFORMATION
Additional EEC-V 216K research and platform information can also be made available for projects that require more than the calibration parameters themselves.
Memory region information and identified areas of the EEC-V 216K PCM memory layout.
Additional information about how EEC-V 216K binaries are organized and where different types of data are located.
Additional research into EEC-V 216K architecture, calibration structure and related binary information.
Need an XDF, DAMOS, A2L or another finished definition format? Custom definition work is available separately.
BEFORE YOU PURCHASE
This product is a professional calibration definition and research reference for the Ford EEC-V 216K platform. It is not a Ford PCM binary, stock calibration, modified calibration, flashing tool or standalone tuning application.
The delivered definition contains the mapped calibration information needed to identify and work with parameters contained within supported EEC-V 216K files.
The information is intentionally provided in a format that is useful beyond a single tuning application. You can use it to create an XDF, DAMOS, A2L-style definition, WinOLS project or another definition format depending on your workflow.
Each mapped scalar and table has been manually mapped and checked. Extensive research and development has gone into locating, identifying and verifying the calibration information contained in this definition.
Because EEC-V binaries, calibration layouts and strategies can differ, always verify that your specific binary matches a supported strategy before making calibration changes.
Ford EEC-V 216K
Get the Ford EEC-V 216K calibration definition from Trent's Tuning and start your project with thousands of manually mapped and checked calibration locations already identified.
Buy Definition - $600